Features• Four or fourteen preset values• Monitor functions for: flow rate, total quantity, number of batches, leakage, process-time, batch-size, power-down.• Automatic restart function for repeatet batch control.• Manual flush-control.• Record of total quantity batched with alarm set-point.• Record of number of batches executed with alarm set-point.• Calibration procedure for the flowmeter.• Full numerical keyboard with twenty industrial micro-switch keys.• User-friendly operation with clear menu structure.• Self learning overrun correction.• Two-stage control.• Four styles of housing are available. Wall-mount housing comes as standard.
ApplicationsBatching of liquids where the batch size changes frequently.Alternative basic models: F030, F130, F131, 310.Alternative advanced model: 326.
Flowmeter Inputs• Reed-switch.• NAMUR.• NPN/PNP pulse.
Status Inputs• Remote control: start / pause / stop / alarm.• Remote control: preset selection 1-4 or 1-14.
Pulse Outputs• Function: Scaled pulse output according to accumulated total (e.g. one pulse every 3.25 gallons). Max. frequency: 10Hz.Remark: with pulse output one-stage control only.• Type: One isolated electro-mechanical make-and-break relay or one passive DC solid-state relay.
Alarm Outputs• Function: Fail-safe alarm output - switched-off in case of an alarm.• Type: One isolated electro-mechanical make-and-break relay or one passive DC solid-state relay.
Analog Outputs• Function: Re-transmitting the flow rate - the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).• Type: One passive isolated 4 – 20mA output.
Control Outputs• Function: Control outputs for one- or two-stage batching with active overrun correction.Remark: with pulse output one control only.• Type: Two isolated electro-mechanical make-and-break relays or two passive DC solid-state relays.
Power Supply• 24V AC/DC.• 115 / 230V AC.
Sensor Supply• 8.2 – 12 – 24V DC.
Explosion Proof• ATEX: II 2 G EEx d IIB T5.
CommunicationFunction: All process data and settings can be read / modified through the communication link as well as a batch can be started / stopped.Protocol: Modbus ASCII / RTU.Interface: RS485 2-wire.