// File:    Fluidwell Batch Controllers Library
// Version: 1.1
// Date:    2009-09-28 17:32:57
//=============================================================================

// following variables should be equal to the entries found in menu.js
var groupName                   = "batchcontrollers"; // menuArrayName
var groupScreen                 = "Batch Controllers"; // menuArrayScreen
var groupLink                   = "batchcontrollers.html"; // menuArrayLink
var groupDatasheet              = "FWPS-BatchControllers_EN_04-06.pdf"; // not available in menu.js

var groupDescriptionTitle       = new Array();
var groupDescriptionImageSmall  = new Array();
var groupDescriptionImageLarge  = new Array();
var groupDescriptionText        = new Array();

var groupEntryName              = new Array();
var groupEntryScreen            = new Array();
var groupEntryList              = new Array();

var groupDescription0Text       = new Array();
groupDescriptionText[0]         = groupDescription0Text;
groupDescriptionTitle[0]        = "Introduction";
groupDescriptionImageSmall[0]   = "";
groupDescriptionImageLarge[0]   = "";
groupDescription0Text[0]        = "The product group &quot;Batch Controllers&quot; offers ten different batch-controllers in the F-Series and 300-Series product ranges. The batch-controllers can be used for accurate dispensing of small amounts of liquids up to the loading of trucks with two-stage control and analog multi-stage control.";
groupDescription0Text[1]        = "Specially designed for the delivery of unknown quantities of product is the delivery controller which can be used for all kinds of products like gasoline, oil and windshield fluid.";
groupDescription0Text[2]        = "The functionality of the batch controllers is based on three main hardware platforms:";
groupDescription0Text[3]        = "-F0-Series platform: these products offer one flowmeter input and one control output for one-stage control only. This is our basic product range.";
groupDescription0Text[4]        = "-F1-Series platform: these products have one flowmeter input as well as external start / stop inputs, multiple outputs for two-stage control or scaled pulse output, analog output and communication option. This is our more advanced product range.";
groupDescription0Text[5]        = "-300-Series platform: these products offer a full numerical keyboard and a multi language alfanumerical display as well as more advanced functionallity. Typically used for frequently varying batch quantities. This is our top range.";
groupDescription0Text[6]        = "The F0- and F1-Series hardware platforms share the same technology, enclosures, display and options but are dedicated to their own typical functionality. The 300-Series has its own dedicated hardware, display and enclosures.";
groupDescription0Text[7]        = "All F-Series models are available for both safe area and hazardous area applications.  Moreover, wireless data re-transmission and remote process monitoring is offered with our M-Series and ProcessMonitor.com products and services.";
groupDescription0Text[8]        = "For an explanation of the various options such as analog and pulse output signals, communication, power supply and enclosures, please read the sections detailing the <A HREF=\"javascript:openmodel('F-Series')\" CLASS=\"ModelLink\"><NOBR>F-Series</NOBR></A> and <A HREF=\"javascript:openmodel('300-Series')\" CLASS=\"ModelLink\"><NOBR>300-Series</NOBR></A> products.";

var groupDescription1Text       = new Array();
groupDescriptionText[1]         = groupDescription1Text;
groupDescriptionTitle[1]        = "Operator information and functions";
groupDescriptionImageSmall[1]   = "";
groupDescriptionImageLarge[1]   = "";
groupDescription1Text[0]        = "The following features are available on all batch controller models. Further product specific features can be found in the products datasheet.";
groupDescription1Text[1]        = "-Clear operator information is a key feature of these products. Essential information is displayed as clear text (e.g. &quot;Press start&quot;) and not as mysterious abbreviations.";
groupDescription1Text[2]        = "-The dedicated display shows two (F-Series) or four (300-Series) lines of information simultaneously along with textlabels like &quot;preset&quot;, &quot;actual&quot; or &quot;accumulated total&quot; so the operator understands the displayed information.";
groupDescription1Text[3]        = "-The preset value and the actual value during the batch process is displayed with its engineering unit. The following units can be selected through software: ml, L, m&sup3;, GAL, USGAL, kg, lb, bbl or no unit.";
groupDescription1Text[4]        = "-Entering the preset value is a basic function, understandable for every operator. For repeatable batches it is not required to re-enter the preset value, simply press start.";
groupDescription1Text[5]        = "-During batching, the displayed actual value can count up to display the batch quantity or count down to display the remaining quantity (F-Series only).";
groupDescription1Text[6]        = "-The active self learning overrun correction compensates the slowness of the control valve as well as unstable line pressure due to a decreasing stock level; a repeating and accurate batch quantity is the result.";
groupDescription1Text[7]        = "-A resettable totalizer is displayed with seven digits.";
groupDescription1Text[8]        = "-A non-resettable accumulated total is displayed with eleven digits and uses the same measuring unit as total and preset value (F-Series only).";
groupDescription1Text[9]        = "-With the maximum preset value, the operator can be protected against incorrect entry of a batch size.";

var groupDescription2Text       = new Array();
groupDescriptionText[2]         = groupDescription2Text;
groupDescriptionTitle[2]        = "Configuration menu";
groupDescriptionImageSmall[2]   = "";
groupDescriptionImageLarge[2]   = "";
groupDescription2Text[0]        = "All configuration settings are accessed via a simple operator menu which can be passcode protected to prevent unauthorized access. Each setting is clearly indicated with an alphanumerical description, therefore avoiding confusing abbreviations and baffling codes. Once familiar with a single F-Series or 300-Series product, you will be able to program all models in the series without a manual. All settings are safely stored in EEPROM or NVRAM memory. The clear and easy structured configuration menu is one of the most appreciated features of these products.";

var groupDescription3Text       = new Array();
groupDescriptionText[3]         = groupDescription3Text;
groupDescriptionTitle[3]        = "Signal input type";
groupDescriptionImageSmall[3]   = "";
groupDescriptionImageLarge[3]   = "";
groupDescription3Text[0]        = "For the F-Series batch controllers, three basic signal input types are available:";
groupDescription3Text[1]        = "-Pulse signals: sine wave (coil) low sensitivity (80mVp-p), sine wave high sensitivity (20mVp-p), Namur, NPN, PNP, reed-switch or active pulses. For most signals a low pass filter can be enabled to ignore pulse bounce. The sine wave input can even be supplied with 10mV or 5mVp-p sensitivity (option ZF and ZG).";
groupDescription3Text[2]        = "-Analog signal: <NOBR>(0)4 &ndash; 20mA</NOBR> or <NOBR>4 &ndash; 20mA</NOBR> input loop powered version. The input signal can be tuned within this range (e.g. from 4.0mA to 10.0mA). To avoid counting at minimum signal, a low cut-off filter is available.";
groupDescription3Text[3]        = "-Analog signal: <NOBR>0 &ndash; 10V DC</NOBR>. The input signal can be  tuned within this range (e.g. from 2.0 to 5.0V DC). A low cut-off filter is available here too, to avoid counting at minimum signal.";
groupDescription3Text[4]        = "The 300-Series batch controller will accept signals from most flowmeters, ranging from PD-meters with reed-switches or hall-effect sensors to other NPN/PNP pulse outputs or Namur-sensors.";

groupEntryName[0]               = "subgroup0";
groupEntryScreen[0]             = "Batch controllers";
groupEntryList[0]               = "f030,f130,f131,f136,310,313,320,326,330";

groupEntryName[1]               = "subgroup1";
groupEntryScreen[1]             = "Dispensers";
groupEntryList[1]               = "f133";