// File:    Fluidwell F010 Library
// Version: 1.1
// Date:    2009-09-28 17:32:59
//=============================================================================

// following variables should be equal to the entries found in products.js
var productName            = "f010";
var productScreen          = "F010";
var productLink            = "f010.html";
var productDatasheet       = "FWDSF010-0909-EN.pdf";
var productSchematicScreen = "f010sch_scr.gif";
var productSchematicPrint  = "f010sch_prn.gif";
var productPhotoScreen     = "f010pho_scr.gif";
var productPhotoPrint      = "f010pho_prn.gif";
var productLCDScreen       = "f010lcd_scr.gif";
var productLCDPrint        = "f010lcd_prn.gif";
var productTitle           = "Flow rate indicator";
var productSubtitle        = "with very large digits";

// following variables are always created as arrays and later filled with strings
var productArrayDescription       = new Array();
var productArrayFeatures          = new Array();
var productArrayApplications      = new Array();
var productArrayInputs            = new Array();
var productArrayInputsFlow        = new Array();
var productArrayInputsTemperature = new Array();
var productArrayInputsLevel       = new Array();
var productArrayInputsPressure    = new Array();
var productArrayInputsStatus      = new Array();
var productArrayInputsGeneral     = new Array();
var productArrayOutputs           = new Array();
var productArrayOutputsPulse      = new Array();
var productArrayOutputsAlarm      = new Array();
var productArrayOutputsAnalog     = new Array();
var productArrayOutputsControl    = new Array();
var productArraySupply            = new Array();
var productArraySupplyPower       = new Array();
var productArraySupplySensor      = new Array();
var productArrayHazardous         = new Array();
var productArrayHazardousIS       = new Array();
var productArrayHazardousNI       = new Array();
var productArrayHazardousEP       = new Array();
var productArrayCommunication     = new Array();

productArrayInputs[0]   = productArrayInputsFlow;
productArrayInputs[1]   = productArrayInputsTemperature;
productArrayInputs[2]   = productArrayInputsLevel;
productArrayInputs[3]   = productArrayInputsPressure;
productArrayInputs[4]   = productArrayInputsStatus;
productArrayInputs[5]   = productArrayInputsGeneral;

productArrayOutputs[0]   = productArrayOutputsPulse;
productArrayOutputs[1]   = productArrayOutputsAlarm;
productArrayOutputs[2]   = productArrayOutputsAnalog;
productArrayOutputs[3]   = productArrayOutputsControl;

productArraySupply[0]   = productArraySupplyPower;
productArraySupply[1]   = productArraySupplySensor;

productArrayHazardous[0]   = productArrayHazardousIS; 
productArrayHazardous[1]   = productArrayHazardousNI; 
productArrayHazardous[2]   = productArrayHazardousEP; 
//=============================================================================
// Main productArray name at productArray [x][0]
// ===== Following is old comment, not implemented this way! =====
// Every array should contain at least 2 items
// If item 1 is empty ('') we make no header and following items are separated by a <BR>
// If an other empty entry is found, we make an <P> separation
// Also, if item 1 is empty, we make the class 'ModelUnboxedB'
// If item 1 has a ! as first char the following items are started with bullits
// The rest of the item 1 text is used as heading
// All lines or items should be followed by a ., but not the headings.

// Make entry 0 the description value?
// Or leftside contains features (list) and applications (no list) and rightside contains multiple lists?

productArrayDescription[0]   = "The F010 is a local indicator with large 26mm (1&quot;) high digits which displays the actual flow rate. The measuring and time unit to be displayed below the flow rate are simply selected through an alphanumeric configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user-friendly solution!<BR>The configuration of K-factors or Span and number of decimals is done through software functions, without any sensitive DIP-switches or trimmers.<BR>A wide range of options further enhance this models capabilities, including Intrinsic Safety for hazardous area applications.";

productArrayFeatures[0]   = "Features";
productArrayFeatures[1]   = "Displays instantaneous flow rate, measuring and time unit.";
productArrayFeatures[2]   = "Very large 26mm (1&quot;) high digits for flow rate.";
productArrayFeatures[3]   = "Selectable on-screen engineering units for flow rate:<BR>mL, L, m&sup3;, mg, g, kg, ton, GAL, bbl, lb, cf, REV, scf, Nm&sup3;, NL, P or no unit.";
productArrayFeatures[4]   = "Selectable on-screen time units for flow rate:<BR>/sec, /min, /hour or /day.";
productArrayFeatures[5]   = "Number of digits for flow rate: 5&frac12;.";
productArrayFeatures[6]   = "Piegraph indication: ten segments.";
productArrayFeatures[7]   = "Green or amber LED backlight with adjustable intensity.";
productArrayFeatures[8]   = "Auto backup of settings in EEPROM memory.";
productArrayFeatures[9]   = "Operational temperature: -40&deg;C to +80&deg;C (-40&deg;F to 178&deg;F).";
productArrayFeatures[10]  = "Easy configuration with clear alphanumerical display.";
productArrayFeatures[11]  = "Very compact design for panel mount, wall mount or field mount applications.";
productArrayFeatures[12]  = "Rugged aluminum or GRP field mount enclosure IP67 / NEMA4X.";

productArrayApplications[0]   = "Applications";
productArrayApplications[1]   = "Flow measurement where a local flow rate indication is required without signal re-transmission or totalizer functionality.";
productArrayApplications[2]   = "Alternative advanced models: <A HREF=\"javascript:openmodel('F012')\" CLASS=\"ModelLink\"><NOBR>F012</NOBR></A>, <A HREF=\"javascript:openmodel('F013')\" CLASS=\"ModelLink\"><NOBR>F013</NOBR></A>, <A HREF=\"javascript:openmodel('F014')\" CLASS=\"ModelLink\"><NOBR>F014</NOBR></A>, <A HREF=\"javascript:openmodel('F016')\" CLASS=\"ModelLink\"><NOBR>F016</NOBR></A>.<BR>Even more advanced models: <A HREF=\"javascript:openmodel('F110')\" CLASS=\"ModelLink\"><NOBR>F110</NOBR></A> and higher.";

productArrayInputsFlow[0]   = "Flowmeter Inputs";
productArrayInputsFlow[1]   = "Pulse type inputs:<BR>Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.";
productArrayInputsFlow[2]   = "<NOBR>(0)4 &ndash; 20mA</NOBR>.";
productArrayInputsFlow[3]   = "<NOBR>0 &ndash; 10V DC</NOBR>.";

productArrayOutputsPulse[0]   = "Pulse Outputs";
productArrayOutputsPulse[1]   = "None.";

productArrayOutputsAlarm[0]   = "Alarm Outputs";
productArrayOutputsAlarm[1]   = "None.";

productArrayOutputsAnalog[0]   = "Analog Outputs";
productArrayOutputsAnalog[1]   = "None.";

productArraySupplyPower[0]   = "Power Supply";
productArraySupplyPower[1]   = "Battery.";
productArraySupplyPower[2]   = "<NOBR>4 &ndash; 20mA</NOBR>. Input Loop-powered.";
productArraySupplyPower[3]   = "8 &ndash; 24V AC/DC.";
productArraySupplyPower[4]   = "115 &ndash; 230V AC.";

productArraySupplySensor[0]   = "Sensor Supply";
productArraySupplySensor[1]   = "3.2, 8.2, 12, 24V DC.";

productArrayHazardousIS[0]   = "Intrinsically Safe";
productArrayHazardousIS[1]   = "<U>ATEX:</U><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 1 G Ex ia IIC T4</NOBR><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 1 D Ex iaD 20 IP 65 / 67 T 100 &deg;C</NOBR>";
productArrayHazardousIS[2]   = "<U>IECEx:</U><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> Ga Ex ia IIC T4</NOBR><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> Ex iaD 20 IP65 / 67 T100 &deg;C</NOBR>";
productArrayHazardousIS[3]   = "<U>CSA:</U><BR><NOBR>I.S. Class I / II / III, Div. 1, Grps A...G, T4</NOBR><BR><NOBR>Class I, Zone 0, AEx ia IIC T4</NOBR>";
productArrayHazardousIS[4]   = "<U>FM:</U><BR><NOBR>I.S. Class I / II / III, Div. 1, Grps A...G, T4</NOBR><BR><NOBR>Class I, Zone 0, AEx ia IIC T4</NOBR>";

productArrayHazardousEP[0]   = "Explosion Proof";
productArrayHazardousEP[1]   = "<U>ATEX:</U><BR> <NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 2 GD EEx d IIB T5</NOBR>";

productArrayCommunication[0]   = "Communication";
productArrayCommunication[1]   = "Only available on F1-Series products.";
