var productTitle           = "Flow rate monitor / totalizer";
var productSubtitle        = "with one high / low alarm output";

// following variables are always created as arrays and later filled with strings
var productArrayDescription       = new Array();
var productArrayFeatures          = new Array();
var productArrayApplications      = new Array();
var productArrayInputs            = new Array();
var productArrayInputsFlow        = new Array();
var productArrayInputsTemperature = new Array();
var productArrayInputsLevel       = new Array();
var productArrayInputsPressure    = new Array();
var productArrayInputsStatus      = new Array();
var productArrayInputsGeneral     = new Array();
var productArrayOutputs           = new Array();
var productArrayOutputsPulse      = new Array();
var productArrayOutputsAlarm      = new Array();
var productArrayOutputsAnalog     = new Array();
var productArrayOutputsControl    = new Array();
var productArraySupply            = new Array();
var productArraySupplyPower       = new Array();
var productArraySupplySensor      = new Array();
var productArrayHazardous         = new Array();
var productArrayHazardousIS       = new Array();
var productArrayHazardousNI       = new Array();
var productArrayHazardousEP       = new Array();
var productArrayCommunication     = new Array();

productArrayInputs[0]   = productArrayInputsFlow;
productArrayInputs[1]   = productArrayInputsTemperature;
productArrayInputs[2]   = productArrayInputsLevel;
productArrayInputs[3]   = productArrayInputsPressure;
productArrayInputs[4]   = productArrayInputsStatus;
productArrayInputs[5]   = productArrayInputsGeneral;

productArrayOutputs[0]   = productArrayOutputsPulse;
productArrayOutputs[1]   = productArrayOutputsAlarm;
productArrayOutputs[2]   = productArrayOutputsAnalog;
productArrayOutputs[3]   = productArrayOutputsControl;

productArraySupply[0]   = productArraySupplyPower;
productArraySupply[1]   = productArraySupplySensor;

productArrayHazardous[0]   = productArrayHazardousIS; 
productArrayHazardous[1]   = productArrayHazardousNI; 
productArrayHazardous[2]   = productArrayHazardousEP; 
//=============================================================================
// Main productArray name at productArray [x][0]
// ===== Following is old comment, not implemented this way! =====
// Every array should contain at least 2 items
// If item 1 is empty ('') we make no header and following items are separated by a <BR>
// If an other empty entry is found, we make an <P> separation
// Also, if item 1 is empty, we make the class 'ModelUnboxedB'
// If item 1 has a ! as first char the following items are started with bullits
// The rest of the item 1 text is used as heading
// All lines or items should be followed by a ., but not the headings.

// Make entry 0 the description value?
// Or leftside contains features (list) and applications (no list) and rightside contains multiple lists?

productArrayDescription[0]   = "The F013 is a versatile flow rate indicator and totalizer with continuous flow rate monitoring feature. It offers the ability to set one low flow rate and one high flow rate alarm value. If desired, an alarm ignore function can be set up to allow for an incorrect flow rate for a certain period of time. The display shows flow rate, total, accumulated total, alarm  values and alarm messages.<BR>On-screen engineering units are easily configured from a comprehensive selection.<BR>A wide range of options further enhance this models capabilities, including Intrinsic Safety for hazardous area applications.";

productArrayFeatures[0]   = "Features";
productArrayFeatures[1]   = "Flow rate monitoring: two alarm values can be set: low and high flow rate alarm.";
productArrayFeatures[2]   = "Alarm values can be changed by the operator or they can be passcode protected.";
productArrayFeatures[3]   = "One alarm output for high, low or both combined flow rate alarms.";
productArrayFeatures[4]   = "Displays total and flow rate simultaneously.";
productArrayFeatures[5]   = "Large digit selection for flow rate or total.";
productArrayFeatures[6]   = "Flow rate: seven 17mm (0.67&quot;) or 8mm (0.31&quot;) digits.";
productArrayFeatures[7]   = "Total - resettable: seven 17mm (0.67&quot;) digits.";
productArrayFeatures[8]   = "Accumulated total - not resettable: eleven 8mm (0.31&quot;) digits.";
productArrayFeatures[9]   = "Separate engineering units for flow rate and total.";
productArrayFeatures[10]  = "Red flashing LED backlight in case of a flow rate alarm; intensity adjustable.";
productArrayFeatures[11]  = "Displays clear alarm messages.";
productArrayFeatures[12]  = "Auto backup of settings and running totals in EEPROM memory.";
productArrayFeatures[13]  = "Operational temperature: -40&deg;C to +80&deg;C (-40&deg;F to 176&deg;F).";
productArrayFeatures[14]  = "Very compact design for panel mount, wall mount or field mount applications.";
productArrayFeatures[15]  = "Rugged aluminum or GRP field mount enclosure IP67 / NEMA4X.";

productArrayApplications[0]   = "Applications";
productArrayApplications[1]   = "Flow measurement where continuous flow rate monitoring is important without signal re-transmission.";
productArrayApplications[2]   = "Alternative advanced models: <A HREF=\"javascript:openmodel('F113')\" CLASS=\"ModelLink\"><NOBR>F113</NOBR></A>, <A HREF=\"javascript:openmodel('F118')\" CLASS=\"ModelLink\"><NOBR>F118</NOBR></A>.";

productArrayInputsFlow[0]   = "Flowmeter Inputs";
productArrayInputsFlow[1]   = "Pulse type inputs:<BR>Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.";
productArrayInputsFlow[2]   = "<NOBR>(0)4 &ndash; 20mA</NOBR>.";
productArrayInputsFlow[3]   = "<NOBR>0 &ndash; 10V DC</NOBR>.";

productArrayOutputsPulse[0]   = "Pulse Outputs";
productArrayOutputsPulse[1]   = "None.";

productArrayOutputsAlarm[0]   = "Alarm Outputs";
productArrayOutputsAlarm[1]   = "<U>Function:</U> Configurable alarm output for high, low or both combined flow rate alarms.";
productArrayOutputsAlarm[2]   = "<U>Type:</U> One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay.";

productArrayOutputsAnalog[0]   = "Analog Outputs";
productArrayOutputsAnalog[1]   = "None.";

productArraySupplyPower[0]   = "Power Supply";
productArraySupplyPower[1]   = "Battery.";
productArraySupplyPower[2]   = "<NOBR>4 &ndash; 20mA</NOBR>. Input Loop-powered.";
productArraySupplyPower[3]   = "8 &ndash; 24V AC/DC.";
productArraySupplyPower[4]   = "115 &ndash; 230V AC.";

productArraySupplySensor[0]   = "Sensor Supply";
productArraySupplySensor[1]   = "3.2, 8.2, 12, 24V DC.";

productArrayHazardousIS[0]   = "Intrinsically Safe";
productArrayHazardousIS[1]   = "<U>ATEX:</U><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 1 G Ex ia IIC T4</NOBR><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 1 D Ex iaD 20 IP 65 / 67 T 100 &deg;C</NOBR>";
productArrayHazardousIS[2]   = "<U>IECEx:</U><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> Ga Ex ia IIC T4</NOBR><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> Ex iaD 20 IP65 / 67 T100 &deg;C</NOBR>";
productArrayHazardousIS[3]   = "<U>CSA:</U><BR><NOBR>I.S. Class I / II / III, Div. 1, Grps A...G, T4</NOBR><BR><NOBR>Class I, Zone 0, AEx ia IIC T4</NOBR>";
productArrayHazardousIS[4]   = "<U>FM:</U><BR><NOBR>I.S. Class I / II / III, Div. 1, Grps A...G, T4</NOBR><BR><NOBR>Class I, Zone 0, AEx ia IIC T4</NOBR>";

productArrayHazardousEP[0]   = "Explosion Proof";
productArrayHazardousEP[1]   = "<U>ATEX:</U><BR> <NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 2 GD EEx d IIB T5</NOBR>";

productArrayCommunication[0]   = "Communication";
productArrayCommunication[1]   = "Only available on F1-Series products.";
