// File:    Fluidwell F016 Library
// Version: 1.1
// Date:    2012-01-04 10:24:59
//=============================================================================

// following variables should be equal to the entries found in products.js
var productName            = "f016";
var productScreen          = "F016";
var productLink            = "f016.html";
var productDatasheet       = "F016-DATA-EN-V1151.pdf";
var productSchematicScreen = "f016sch_scr.gif";
var productSchematicPrint  = "f016sch_prn.gif";
var productPhotoScreen     = "f016pho_scr.gif";
var productPhotoPrint      = "f016pho_prn.gif";
var productLCDScreen       = "f016lcd_scr.gif";
var productLCDPrint        = "f016lcd_prn.gif";
var productTitle           = "Flow rate indicator / totalizer";
var productSubtitle        = "with linearization and pulse output";

// following variables are always created as arrays and later filled with strings
var productArrayDescription       = new Array();
var productArrayFeatures          = new Array();
var productArrayApplications      = new Array();
var productArrayInputs            = new Array();
var productArrayInputsFlow        = new Array();
var productArrayInputsTemperature = new Array();
var productArrayInputsLevel       = new Array();
var productArrayInputsPressure    = new Array();
var productArrayInputsStatus      = new Array();
var productArrayInputsGeneral     = new Array();
var productArrayOutputs           = new Array();
var productArrayOutputsPulse      = new Array();
var productArrayOutputsAlarm      = new Array();
var productArrayOutputsAnalog     = new Array();
var productArrayOutputsControl    = new Array();
var productArraySupply            = new Array();
var productArraySupplyPower       = new Array();
var productArraySupplySensor      = new Array();
var productArrayHazardous         = new Array();
var productArrayHazardousIS       = new Array();
var productArrayHazardousNI       = new Array();
var productArrayHazardousEP       = new Array();
var productArrayCommunication     = new Array();

productArrayInputs[0]   = productArrayInputsFlow;
productArrayInputs[1]   = productArrayInputsTemperature;
productArrayInputs[2]   = productArrayInputsLevel;
productArrayInputs[3]   = productArrayInputsPressure;
productArrayInputs[4]   = productArrayInputsStatus;
productArrayInputs[5]   = productArrayInputsGeneral;

productArrayOutputs[0]   = productArrayOutputsPulse;
productArrayOutputs[1]   = productArrayOutputsAlarm;
productArrayOutputs[2]   = productArrayOutputsAnalog;
productArrayOutputs[3]   = productArrayOutputsControl;

productArraySupply[0]   = productArraySupplyPower;
productArraySupply[1]   = productArraySupplySensor;

productArrayHazardous[0]   = productArrayHazardousIS; 
productArrayHazardous[1]   = productArrayHazardousNI; 
productArrayHazardous[2]   = productArrayHazardousEP; 
//=============================================================================
// Main productArray name at productArray [x][0]
// ===== Following is old comment, not implemented this way! =====
// Every array should contain at least 2 items
// If item 1 is empty ('') we make no header and following items are separated by a <BR>
// If an other empty entry is found, we make an <P> separation
// Also, if item 1 is empty, we make the class 'ModelUnboxedB'
// If item 1 has a ! as first char the following items are started with bullits
// The rest of the item 1 text is used as heading
// All lines or items should be followed by a ., but not the headings.

// Make entry 0 the description value?
// Or leftside contains features (list) and applications (no list) and rightside contains multiple lists?

productArrayDescription[0]   = "The F016 is a local indicator which displays the actual flow rate, total and accumulated total. In addition to the average K-Factor or Span, eight linearization points can be entered with their frequencies or values. The unit will interpolate between these points, greatly enhancing accuracy in any flow range, even for very low frequency applications. This linearization affects all displayed information as well as the pulse output.<BR>On-screen engineering units are easily configured from a comprehensive selection.<BR>A wide range of options further enhance this models capabilities, including Intrinsic Safety for hazardous area applications.";

productArrayFeatures[0]   = "Features";
productArrayFeatures[1]   = "Eight point linearization of the flow curve - with interpolation.";
productArrayFeatures[2]   = "Scaled pulse output reflecting the accumulated total.";
productArrayFeatures[3]   = "Displays total and flow rate simultaneously.";
productArrayFeatures[4]   = "Large digit selection for flow rate or total.";
productArrayFeatures[5]   = "Flow rate: seven 17mm (0.67&quot;) or 8mm (0.31&quot;) digits.";
productArrayFeatures[6]   = "Total - resettable: seven 17mm (0.67&quot;) digits.";
productArrayFeatures[7]   = "Accumulated total - not resettable: eleven 8mm (0.31&quot;) digits.";
productArrayFeatures[8]   = "Separate engineering units for flow rate and total.";
productArrayFeatures[9]   = "Green or amber LED backlight with adjustable intensity.";
productArrayFeatures[10]  = "Auto backup of settings and running totals in EEPROM memory.";
productArrayFeatures[11]  = "Operational temperature: -40&deg;C to +80&deg;C (-40&deg;F to 176&deg;F).";
productArrayFeatures[12]  = "Easy configuration with clear alphanumerical display.";
productArrayFeatures[13]  = "Very compact design for panel mount, wall mount or field mount applications.";
productArrayFeatures[14]  = "Rugged aluminum or GRP field mount enclosure IP67 / NEMA4X.";

productArrayApplications[0]   = "Applications";
productArrayApplications[1]   = "Liquid flow measurement with mechanic flowmeters where a precise calculation over the full measurement range is required.";
productArrayApplications[2]   = "Alternative advanced models: <A HREF=\"javascript:openmodel('F112')\" CLASS=\"ModelLink\"><NOBR>F112</NOBR></A>, <A HREF=\"javascript:openmodel('F118')\" CLASS=\"ModelLink\"><NOBR>F118</NOBR></A>.";

productArrayInputsFlow[0]   = "Flowmeter Inputs";
productArrayInputsFlow[1]   = "Pulse type inputs:<BR>Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.";

productArrayOutputsPulse[0]   = "Pulse Outputs";
productArrayOutputsPulse[1]   = "<U>Function:</U> Scaled pulse output according to accumulated total (e.g. one pulse every 3.25 gallons).<BR> Max. frequency: 500Hz.<BR> Adjustable pulse length from 1 msec. to 10 seconds.";
productArrayOutputsPulse[2]   = "<U>Type:</U> One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay.";

productArrayOutputsAlarm[0]   = "Alarm Outputs";
productArrayOutputsAlarm[1]   = "None.";

productArrayOutputsAnalog[0]   = "Analog Outputs";
productArrayOutputsAnalog[1]   = "None.";

productArraySupplyPower[0]   = "Power Supply";
productArraySupplyPower[1]   = "Battery.";
productArraySupplyPower[2]   = "8 &ndash; 24V AC/DC.";
productArraySupplyPower[3]   = "115 &ndash; 230V AC.";
productArraySupplyPower[4]   = "3.2, 8.2, 12, 24V DC.";

productArrayHazardousIS[0]   = "Intrinsically Safe";
productArrayHazardousIS[1]   = "<U>ATEX:</U><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 1 G Ex ia IIC T4</NOBR><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 1 D Ex iaD 20 IP 65 / 67 T 100 &deg;C</NOBR>";
productArrayHazardousIS[2]   = "<U>IECEx:</U><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> Ga Ex ia IIC T4</NOBR><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> Ex iaD 20 IP65 / 67 T100 &deg;C</NOBR>";
productArrayHazardousIS[3]   = "<U>CSA:</U><BR><NOBR>I.S. Class I / II / III, Div. 1, Grps A...G, T4</NOBR><BR><NOBR>Class I, Zone 0, AEx ia IIC T4</NOBR>";
productArrayHazardousIS[4]   = "<U>FM:</U><BR><NOBR>I.S. Class I / II / III, Div. 1, Grps A...G, T4</NOBR><BR><NOBR>Class I, Zone 0, AEx ia IIC T4</NOBR>";

productArrayHazardousEP[0]   = "Explosion Proof";
productArrayHazardousEP[1]   = "<U>ATEX:</U><BR> <NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 2 GD EEx d IIB T5</NOBR>";

productArrayCommunication[0]   = "Communication";
productArrayCommunication[1]   = "Only available on F1-Series products.";
