// File:    Fluidwell F113 Library
// Version: 1.1
// Date:    2012-01-04 10:25:01
//=============================================================================

// following variables should be equal to the entries found in products.js
var productName            = "f113";
var productScreen          = "F113";
var productLink            = "f113.html";
var productDatasheet       = "F113-DATA-EN-V1151.pdf";
var productSchematicScreen = "f113sch_scr.gif";
var productSchematicPrint  = "f113sch_prn.gif";
var productPhotoScreen     = "f113pho_scr.gif";
var productPhotoPrint      = "f113pho_prn.gif";
var productLCDScreen       = "f113lcd_scr.gif";
var productLCDPrint        = "f113lcd_prn.gif";
var productTitle           = "Flow rate monitor / totalizer";
var productSubtitle        = "with high / low alarms, analog and pulse outputs";

// following variables are always created as arrays and later filled with strings
var productArrayDescription       = new Array();
var productArrayFeatures          = new Array();
var productArrayApplications      = new Array();
var productArrayInputs            = new Array();
var productArrayInputsFlow        = new Array();
var productArrayInputsTemperature = new Array();
var productArrayInputsLevel       = new Array();
var productArrayInputsPressure    = new Array();
var productArrayInputsStatus      = new Array();
var productArrayInputsGeneral     = new Array();
var productArrayOutputs           = new Array();
var productArrayOutputsPulse      = new Array();
var productArrayOutputsAlarm      = new Array();
var productArrayOutputsAnalog     = new Array();
var productArrayOutputsControl    = new Array();
var productArraySupply            = new Array();
var productArraySupplyPower       = new Array();
var productArraySupplySensor      = new Array();
var productArrayHazardous         = new Array();
var productArrayHazardousIS       = new Array();
var productArrayHazardousNI       = new Array();
var productArrayHazardousEP       = new Array();
var productArrayCommunication     = new Array();

productArrayInputs[0]   = productArrayInputsFlow;
productArrayInputs[1]   = productArrayInputsTemperature;
productArrayInputs[2]   = productArrayInputsLevel;
productArrayInputs[3]   = productArrayInputsPressure;
productArrayInputs[4]   = productArrayInputsStatus;
productArrayInputs[5]   = productArrayInputsGeneral;

productArrayOutputs[0]   = productArrayOutputsPulse;
productArrayOutputs[1]   = productArrayOutputsAlarm;
productArrayOutputs[2]   = productArrayOutputsAnalog;
productArrayOutputs[3]   = productArrayOutputsControl;

productArraySupply[0]   = productArraySupplyPower;
productArraySupply[1]   = productArraySupplySensor;

productArrayHazardous[0]   = productArrayHazardousIS; 
productArrayHazardous[1]   = productArrayHazardousNI; 
productArrayHazardous[2]   = productArrayHazardousEP; 
//=============================================================================
// Main productArray name at productArray [x][0]
// ===== Following is old comment, not implemented this way! =====
// Every array should contain at least 2 items
// If item 1 is empty ('') we make no header and following items are separated by a <BR>
// If an other empty entry is found, we make an <P> separation
// Also, if item 1 is empty, we make the class 'ModelUnboxedB'
// If item 1 has a ! as first char the following items are started with bullits
// The rest of the item 1 text is used as heading
// All lines or items should be followed by a ., but not the headings.

// Make entry 0 the description value?
// Or leftside contains features (list) and applications (no list) and rightside contains multiple lists?

productArrayDescription[0]   = "The F113 is a versatile flow rate indicator and totalizer with continuous flow rate monitoring feature. It offers the ability to set two low flow rate and two high flow rate alarm values. If desired, an alarm ignore function can be set up to allow for an incorrect flow rate for a certain period of time. Up to five outputs are available to transmit flow rate, alarm conditions and accumulated total.<BR>The display shows flow rate, total, accumulated total, alarm values, alarm messages and status. On-screen engineering units are easily configured from a comprehensive selection.<BR>A wide range of options further enhance this models capabilities, including Intrinsic Safety for hazardous area applications and full Modbus communication.";

productArrayFeatures[0]   = "Features";
productArrayFeatures[1]   = "Flow rate monitoring: four alarm values can be set: low-low, low, high and high-high flow rate alarm.";
productArrayFeatures[2]   = "Alarm values can be changed by the operator or they can be passcode protected.";
productArrayFeatures[3]   = "Alarm ignore function allows an incorrect flow rate for a certain period of time.";
productArrayFeatures[4]   = "Analog and pulse outputs.";
productArrayFeatures[5]   = "Displays total and flow rate simultaneously.";
productArrayFeatures[6]   = "Large digit selection for flow rate or total.";
productArrayFeatures[7]   = "Flow rate: seven 17mm (0.67&quot;) or 8mm (0.31&quot;) digits.";
productArrayFeatures[8]   = "Total - resettable: seven 17mm (0.67&quot;) digits.";
productArrayFeatures[9]   = "Accumulated total - not resettable: eleven 8mm (0.31&quot;) digits.";
productArrayFeatures[10]  = "Separate engineering units for flow rate and total on the display.";
productArrayFeatures[11]  = "Up to four configurable alarm or scaled pulse outputs.";
productArrayFeatures[12]  = "Displays clear alarm messages.";
productArrayFeatures[13]  = "Green LED backlight.";
productArrayFeatures[14]  = "Auto backup of settings and running totals in EEPROM memory.";
productArrayFeatures[15]  = "Operational temperature: -40&deg;C to +80&deg;C (-40&deg;F to 176&deg;F).";
productArrayFeatures[16]  = "Very compact design for panel mount, wall mount or field mount applications.";
productArrayFeatures[17]  = "Rugged aluminum or GRP field mount enclosure IP67 / NEMA4X.";

productArrayApplications[0]   = "Applications";
productArrayApplications[1]   = "Liquid flow measurement where continues flow rate monitoring is important. Also re-transmission of the flow rate and/or totalizer functions or serial communication is required.";
productArrayApplications[2]   = "Alternative basic model: <A HREF=\"javascript:openmodel('F013')\" CLASS=\"ModelLink\"><NOBR>F013</NOBR></A>.<BR>Alternative advanced model: <A HREF=\"javascript:openmodel('F118')\" CLASS=\"ModelLink\"><NOBR>F118</NOBR></A>.";

productArrayInputsFlow[0]   = "Flowmeter Inputs";
productArrayInputsFlow[1]   = "Pulse type inputs:<BR>Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.";
productArrayInputsFlow[2]   = "<NOBR>(0)4 &ndash; 20mA</NOBR>.";
productArrayInputsFlow[3]   = "<NOBR>0 &ndash; 10V DC</NOBR>.";

productArrayInputsStatus[0]   = "Status Inputs";
productArrayInputsStatus[1]   = "Remote control: external reset for clearing total or to disable manual clearing through the keypad.";

productArrayOutputsPulse[0]   = "Pulse Outputs";
productArrayOutputsPulse[1]   = "<U>Function:</U> Scaled pulse output according to accumulated total (e.g. a pulse every 3.25 gallons).<BR>Max. frequency: 64Hz.<BR>Adjustable pulse length from  8 msec. to 2 seconds.";
productArrayOutputsPulse[2]   = "<U>Type:</U> Up to three passive NPN transistors or active PNP transistors or up to four isolated electro-mechanical relays.";

productArrayOutputsAlarm[0]   = "Alarm Outputs";
productArrayOutputsAlarm[1]   = "<U>Function:</U> Configurable alarm outputs for low-low, low, high, high-high or all combined flow rate alarms.";
productArrayOutputsAlarm[2]   = "<U>Type:</U> Up to three passive NPN transistors or active PNP transistors or up to four isolated electro-mechanical relays.";

productArrayOutputsAnalog[0]   = "Analog Outputs";
productArrayOutputsAnalog[1]   = "<U>Function:</U> Re-transmitting the flow rate - the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).";
productArrayOutputsAnalog[2]   = "<U>Type:</U> One passive isolated, floating or loop powered <NOBR>4 &ndash; 20mA</NOBR> output or one active <NOBR>(0)4 &ndash; 20mA</NOBR> or <NOBR>0 &ndash; 10V DC</NOBR> output.";

productArraySupplyPower[0]   = "Power Supply";
productArraySupplyPower[1]   = "Battery.";
productArraySupplyPower[2]   = "<NOBR>4 &ndash; 20mA</NOBR> Loop-powered.";
productArraySupplyPower[3]   = "8 &ndash; 24V AC/DC.";
productArraySupplyPower[4]   = "115 &ndash; 230V AC.";

productArraySupplySensor[0]   = "Sensor Supply";
productArraySupplySensor[1]   = "3.2, 8.2, 12, 24V DC.";

productArrayHazardousIS[0]   = "Intrinsically Safe";
productArrayHazardousIS[1]   = "<U>ATEX:</U><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 1 G Ex ia IIB/IIC T4 Ga</NOBR><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 1 D Ex ia IIIC T100 &deg;C Da IP6X</NOBR>";
productArrayHazardousIS[2]   = "<U>IECEx:</U><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> Ex ia IIC/IIB T4 Ga</NOBR><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> Ex ia IIIC T100 &deg;C Da IP6X</NOBR>";

productArrayHazardousEP[0]   = "Explosion Proof";
productArrayHazardousEP[1]   = "ATEX: <NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 2 G EEx d IIB T5</NOBR>";

productArrayCommunication[0]   = "Communication";
productArrayCommunication[1]   = "<U>Function:</U> All process data and settings can be read and modified through the communication link.";
productArrayCommunication[2]   = "<U>Protocol:</U> Modbus ASCII / RTU.";
productArrayCommunication[3]   = "<U>Interface:</U> RS232 / RS485 2-wire or 4-wire / TTL.";
