// File:    Fluidwell F118 Library
// Version: 1.1
// Date:    2012-01-04 10:25:02
//=============================================================================

// following variables should be equal to the entries found in products.js
var productName            = "f118";
var productScreen          = "F118";
var productLink            = "f118.html";
var productDatasheet       = "F118-DATA-EN-V1151.pdf";
var productSchematicScreen = "f118sch_scr.gif";
var productSchematicPrint  = "f118sch_prn.gif";
var productPhotoScreen     = "f118pho_scr.gif";
var productPhotoPrint      = "f118pho_prn.gif";
var productLCDScreen       = "f118lcd_scr.gif";
var productLCDPrint        = "f118lcd_prn.gif";
var productTitle           = "Flow rate monitor / totalizer";
var productSubtitle        = "with linearization, high / low alarms, analog and pulse outputs";

// following variables are always created as arrays and later filled with strings
var productArrayDescription       = new Array();
var productArrayFeatures          = new Array();
var productArrayApplications      = new Array();
var productArrayInputs            = new Array();
var productArrayInputsFlow        = new Array();
var productArrayInputsTemperature = new Array();
var productArrayInputsLevel       = new Array();
var productArrayInputsPressure    = new Array();
var productArrayInputsStatus      = new Array();
var productArrayInputsGeneral     = new Array();
var productArrayOutputs           = new Array();
var productArrayOutputsPulse      = new Array();
var productArrayOutputsAlarm      = new Array();
var productArrayOutputsAnalog     = new Array();
var productArrayOutputsControl    = new Array();
var productArraySupply            = new Array();
var productArraySupplyPower       = new Array();
var productArraySupplySensor      = new Array();
var productArrayHazardous         = new Array();
var productArrayHazardousIS       = new Array();
var productArrayHazardousNI       = new Array();
var productArrayHazardousEP       = new Array();
var productArrayCommunication     = new Array();

productArrayInputs[0]   = productArrayInputsFlow;
productArrayInputs[1]   = productArrayInputsTemperature;
productArrayInputs[2]   = productArrayInputsLevel;
productArrayInputs[3]   = productArrayInputsPressure;
productArrayInputs[4]   = productArrayInputsStatus;
productArrayInputs[5]   = productArrayInputsGeneral;

productArrayOutputs[0]   = productArrayOutputsPulse;
productArrayOutputs[1]   = productArrayOutputsAlarm;
productArrayOutputs[2]   = productArrayOutputsAnalog;
productArrayOutputs[3]   = productArrayOutputsControl;

productArraySupply[0]   = productArraySupplyPower;
productArraySupply[1]   = productArraySupplySensor;

productArrayHazardous[0]   = productArrayHazardousIS; 
productArrayHazardous[1]   = productArrayHazardousNI; 
productArrayHazardous[2]   = productArrayHazardousEP; 
//=============================================================================
// Main productArray name at productArray [x][0]
// ===== Following is old comment, not implemented this way! =====
// Every array should contain at least 2 items
// If item 1 is empty ('') we make no header and following items are separated by a <BR>
// If an other empty entry is found, we make an <P> separation
// Also, if item 1 is empty, we make the class 'ModelUnboxedB'
// If item 1 has a ! as first char the following items are started with bullits
// The rest of the item 1 text is used as heading
// All lines or items should be followed by a ., but not the headings.

// Make entry 0 the description value?
// Or leftside contains features (list) and applications (no list) and rightside contains multiple lists?

productArrayDescription[0]   = "The F118 is a versatile flow rate indicator and totalizer with the ability to precisely linearize the flowmeter signal. In addition to the average K-Factor or Span, ten linearization points can be entered with their frequencies or values. The unit will interpolate between these points, greatly enhancing accuracy in any flow range, even for very low frequency applications. Moreover, a continuous flow rate monitoring feature is available with high and low flow rate alarm values and up to three alarm outputs. Flow rate and total are transmitted with an analog and scaled pulse output.<BR>The display shows flow rate, total, accumulated total, alarm values, alarm messages and status. On-screen engineering units are easily configured from a comprehensive selection.<BR>A wide range of options further enhance this models capabilities, including Intrinsic Safety for hazardous area applications and full Modbus communication.";

productArrayFeatures[0]   = "Features";
productArrayFeatures[1]   = "Ten point linearization of the flow curve - with interpolation.";
productArrayFeatures[2]   = "Flow rate monitoring: two alarm values can be set: low and high flow rate alarm.";
productArrayFeatures[3]   = "Alarm values can be changed by the operator or they can be passcode protected.";
productArrayFeatures[4]   = "Analog and pulse outputs.";
productArrayFeatures[5]   = "Displays total and flow rate simultaneously.";
productArrayFeatures[6]   = "Flow rate: seven 8mm (0.31&quot;) digits.";
productArrayFeatures[7]   = "Total - resettable: seven 17mm (0.67&quot;) digits.";
productArrayFeatures[8]   = "Accumulated total - not resettable: eleven 8mm (0.31&quot;) digits.";
productArrayFeatures[9]   = "Separate engineering units for flow rate and total on the display.";
productArrayFeatures[10]  = "Up to three configurable alarm or scaled pulse outputs.";
productArrayFeatures[11]  = "Displays clear alarm messages.";
productArrayFeatures[12]  = "Green LED backlight.";
productArrayFeatures[13]  = "Auto backup of settings and running totals in EEPROM memory.";
productArrayFeatures[14]  = "Operational temperature: -40&deg;C to +80&deg;C (-40&deg;F to 176&deg;F).";
productArrayFeatures[15]  = "Very compact design for panel mount, wall mount or field mount applications.";
productArrayFeatures[16]  = "Rugged aluminum or GRP field mount enclosure IP67 / NEMA4X.";

productArrayApplications[0]   = "Applications";
productArrayApplications[1]   = "Liquid flow measurement with mechanic flowmeters where a precise calculation over the full measurement range and continuous flow rate monitoring is required.";
productArrayApplications[2]   = "Alternative basic models: <A HREF=\"javascript:openmodel('F016')\" CLASS=\"ModelLink\"><NOBR>F016</NOBR></A>, <A HREF=\"javascript:openmodel('F112')\" CLASS=\"ModelLink\"><NOBR>F112</NOBR></A>.";

productArrayInputsFlow[0]   = "Flowmeter Inputs";
productArrayInputsFlow[1]   = "Pulse type inputs:<BR>Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.";
productArrayInputsFlow[2]   = "<NOBR>(0)4 &ndash; 20mA</NOBR>.";
productArrayInputsFlow[3]   = "<NOBR>0 &ndash; 10V DC</NOBR>.";

productArrayOutputsPulse[0]   = "Pulse Outputs";
productArrayOutputsPulse[1]   = "<U>Function:</U> Scaled pulse output according to linearized accumulated total (e.g. a pulse every 3.25 gallons).<BR>Max. frequency: 64Hz.<BR>Adjustable pulse length from  8 msec. to 2 seconds.";
productArrayOutputsPulse[2]   = "<U>Type:</U> Up to three passive NPN transistors, active PNP transistors or isolated electro-mechanical relays.";

productArrayOutputsAlarm[0]   = "Alarm Outputs";
productArrayOutputsAlarm[1]   = "<U>Function:</U> Configurable alarm outputs for low, high or both combined flow rate alarms.";
productArrayOutputsAlarm[2]   = "<U>Type:</U> Up to three passive NPN transistors, active PNP transistors or isolated electro-mechanical relays.";

productArrayOutputsAnalog[0]   = "Analog Outputs";
productArrayOutputsAnalog[1]   = "<U>Function:</U> Re-transmitting the linearized flow rate - the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).";
productArrayOutputsAnalog[2]   = "<U>Type:</U> One passive isolated, floating or loop powered <NOBR>4 &ndash; 20mA</NOBR> output or one active <NOBR>(0)4 &ndash; 20mA</NOBR> or <NOBR>0 &ndash; 10V DC</NOBR> output.";

productArraySupplyPower[0]   = "Power Supply";
productArraySupplyPower[1]   = "Battery.";
productArraySupplyPower[2]   = "<NOBR>4 &ndash; 20mA</NOBR> Loop-powered.";
productArraySupplyPower[3]   = "8 &ndash; 24V AC/DC.";
productArraySupplyPower[4]   = "115 &ndash; 230V AC.";

productArraySupplySensor[0]   = "Sensor Supply";
productArraySupplySensor[1]   = "3.2, 8.2, 12, 24V DC.";

productArrayHazardousIS[0]   = "Intrinsically Safe";
productArrayHazardousIS[1]   = "<U>ATEX:</U><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 1 G Ex ia IIB/IIC T4 Ga</NOBR><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 1 D Ex ia IIIC T100 &deg;C Da IP6X</NOBR>";
productArrayHazardousIS[2]   = "<U>IECEx:</U><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> Ex ia IIC/IIB T4 Ga</NOBR><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> Ex ia IIIC T100 &deg;C Da IP6X</NOBR>";

productArrayHazardousEP[0]   = "Explosion Proof";
productArrayHazardousEP[1]   = "ATEX: <NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 2 G EEx d IIB T5</NOBR>";

productArrayCommunication[0]   = "Communication";
productArrayCommunication[1]   = "<U>Function:</U> All process data and settings can be read and modified through the communication link.";
productArrayCommunication[2]   = "<U>Protocol:</U> Modbus RTU.";
productArrayCommunication[3]   = "<U>Interface:</U> RS232 / RS485 2-wire or 4-wire / TTL.";
