// File:    Fluidwell F153 Library
// Version: 1.1
// Date:    2012-01-04 10:25:03
//=============================================================================

// following variables should be equal to the entries found in products.js
var productName            = "f153";
var productScreen          = "F153";
var productLink            = "f153.html";
var productDatasheet       = "F153-DATA-EN-V1151.pdf";
var productSchematicScreen = "f153sch_scr.gif";
var productSchematicPrint  = "f153sch_prn.gif";
var productPhotoScreen     = "f153pho_scr.gif";
var productPhotoPrint      = "f153pho_prn.gif";
var productLCDScreen       = "f153lcd_scr.gif";
var productLCDPrint        = "f153lcd_prn.gif";
var productTitle           = "Pressure monitor";
var productSubtitle        = "with high / low alarms and analog outputs";

// following variables are always created as arrays and later filled with strings
var productArrayDescription       = new Array();
var productArrayFeatures          = new Array();
var productArrayApplications      = new Array();
var productArrayInputs            = new Array();
var productArrayInputsFlow        = new Array();
var productArrayInputsTemperature = new Array();
var productArrayInputsLevel       = new Array();
var productArrayInputsPressure    = new Array();
var productArrayInputsStatus      = new Array();
var productArrayInputsGeneral     = new Array();
var productArrayOutputs           = new Array();
var productArrayOutputsPulse      = new Array();
var productArrayOutputsAlarm      = new Array();
var productArrayOutputsAnalog     = new Array();
var productArrayOutputsControl    = new Array();
var productArraySupply            = new Array();
var productArraySupplyPower       = new Array();
var productArraySupplySensor      = new Array();
var productArrayHazardous         = new Array();
var productArrayHazardousIS       = new Array();
var productArrayHazardousNI       = new Array();
var productArrayHazardousEP       = new Array();
var productArrayCommunication     = new Array();

productArrayInputs[0]   = productArrayInputsFlow;
productArrayInputs[1]   = productArrayInputsTemperature;
productArrayInputs[2]   = productArrayInputsLevel;
productArrayInputs[3]   = productArrayInputsPressure;
productArrayInputs[4]   = productArrayInputsStatus;
productArrayInputs[5]   = productArrayInputsGeneral;

productArrayOutputs[0]   = productArrayOutputsPulse;
productArrayOutputs[1]   = productArrayOutputsAlarm;
productArrayOutputs[2]   = productArrayOutputsAnalog;
productArrayOutputs[3]   = productArrayOutputsControl;

productArraySupply[0]   = productArraySupplyPower;
productArraySupply[1]   = productArraySupplySensor;

productArrayHazardous[0]   = productArrayHazardousIS; 
productArrayHazardous[1]   = productArrayHazardousNI; 
productArrayHazardous[2]   = productArrayHazardousEP; 
//=============================================================================
// Main productArray name at productArray [x][0]
// ===== Following is old comment, not implemented this way! =====
// Every array should contain at least 2 items
// If item 1 is empty ('') we make no header and following items are separated by a <BR>
// If an other empty entry is found, we make an <P> separation
// Also, if item 1 is empty, we make the class 'ModelUnboxedB'
// If item 1 has a ! as first char the following items are started with bullits
// The rest of the item 1 text is used as heading
// All lines or items should be followed by a ., but not the headings.

// Make entry 0 the description value?
// Or leftside contains features (list) and applications (no list) and rightside contains multiple lists?

productArrayDescription[0]   = "The F153 is a versatile pressure indicator featuring continuous pressure monitoring. It offers the ability to set two low and two high pressure alarm values. If desired, an ignore function can be set up to allow for an incorrect temperature for a certain period of time. Up to five outputs are available to transmit alarm conditions and actual pressure.<BR>The display shows the actual pressure, alarm values, alarm messages and status. On-screen engineering units are easily configured from a comprehensive selection.<BR>A wide range of options further enhance this models capabilities, including Intrinsic Safety for hazardous area applications and full Modbus communication.";

productArrayFeatures[0]   = "Features";
productArrayFeatures[1]   = "Pressure monitoring: four alarm values can be set: low-low, low, high and high-high pressure alarm.";
productArrayFeatures[2]   = "Alarm values can be changed by the operator or they can be passcode protected.";
productArrayFeatures[3]   = "Analog output to transmit the actual pressure.";
productArrayFeatures[4]   = "Pressure and alarm values: six large 17mm (0.67&quot;) digits.";
productArrayFeatures[5]   = "Displays pressure, measuring unit and alarm messages simultaneously.";
productArrayFeatures[6]   = "Alarm ignore function allows an incorrect pressure for a certain period of time.";
productArrayFeatures[7]   = "Selectable on-screen engineering units:<BR>mBar - Bar - PSI or no unit";
productArrayFeatures[8]   = "Green LED backlight.";
productArrayFeatures[9]   = "Backup of settings in EEPROM memory.";
productArrayFeatures[10]  = "Operational temperature: -40&deg;C to +80&deg;C (-40&deg;F to 176&deg;F).";
productArrayFeatures[11]  = "Very compact design for panel mount, wall mount or field mount applications.";
productArrayFeatures[12]  = "Rugged aluminum or GRP field mount enclosure IP67 / NEMA4X.";

productArrayApplications[0]   = "Applications";
productArrayApplications[1]   = "For applications where continuous pressure measurement and monitoring is important. Also signal re-transmission of the actual pressure or serial communication is required.";
productArrayApplications[2]   = "Alternative basic models: <A HREF=\"javascript:openmodel('F050')\" CLASS=\"ModelLink\"><NOBR>F050</NOBR></A>, <A HREF=\"javascript:openmodel('F053')\" CLASS=\"ModelLink\"><NOBR>F053</NOBR></A>.";

productArrayInputsPressure[0]   = "Pressure Inputs";
productArrayInputsPressure[1]   = "<NOBR>(0)4 &ndash; 20mA</NOBR>.";
productArrayInputsPressure[2]   = "<NOBR>0 &ndash; 10V DC</NOBR>.";

productArrayOutputsAlarm[0]   = "Alarm Outputs";
productArrayOutputsAlarm[1]   = "<U>Function:</U> Configurable alarm outputs for low-low, low, high, high-high or all combined pressure alarms.";
productArrayOutputsAlarm[2]   = "<U>Type:</U> Up to three passive NPN transistors or active PNP transistors or up to four isolated electro-mechanical relays.";

productArrayOutputsAnalog[0]   = "Analog Outputs";
productArrayOutputsAnalog[1]   = "<U>Function:</U> Re-transmitting the actual pressure - the output can be scaled to any range (e.g. -20&deg;C to +200&deg;C).";
productArrayOutputsAnalog[2]   = "<U>Type:</U> One passive isolated, floating or loop powered <NOBR>4 &ndash; 20mA</NOBR> output or one active <NOBR>(0)4 &ndash; 20mA</NOBR> or <NOBR>0 &ndash; 10V DC</NOBR> output.";

productArraySupplyPower[0]   = "Power Supply";
productArraySupplyPower[1]   = "Battery.";
productArraySupplyPower[2]   = "<NOBR>4 &ndash; 20mA</NOBR> Loop-powered.";
productArraySupplyPower[3]   = "8 &ndash; 24V AC/DC.";
productArraySupplyPower[4]   = "115 &ndash; 230V AC.";

productArraySupplySensor[0]   = "Sensor Supply";
productArraySupplySensor[1]   = "8.2, 12, 24V DC.";

productArrayHazardousIS[0]   = "Intrinsically Safe";
productArrayHazardousIS[1]   = "<U>ATEX:</U><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 1 G Ex ia IIB/IIC T4 Ga</NOBR><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 1 D Ex ia IIIC T100 &deg;C Da IP6X</NOBR>";
productArrayHazardousIS[2]   = "<U>IECEx:</U><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> Ex ia IIC/IIB T4 Ga</NOBR><BR><NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> Ex ia IIIC T100 &deg;C Da IP6X</NOBR>";

productArrayHazardousEP[0]   = "Explosion Proof";
productArrayHazardousEP[1]   = "ATEX: <NOBR><IMG SRC=\"images/exi_exl.gif\" HEIGHT=\"15\" WIDTH=\"18\" ALIGN=\"TEXTTOP\"> II 2 G EEx d IIB T5</NOBR>";

productArrayCommunication[0]   = "Communication";
productArrayCommunication[1]   = "<U>Function:</U> All process data and settings can be read and modified through the communication link.";
productArrayCommunication[2]   = "<U>Protocol:</U> Modbus ASCII / RTU.";
productArrayCommunication[3]   = "<U>Interface:</U> RS232 / RS485 2-wire or 4-wire / TTL.";
