Features• Displays instantaneous flow rate, measuring and time unit.• Very large 26mm (1") high digits for flow rate.• Selectable on-screen engineering units for flow rate:mL, L, m³, mg, g, kg, ton, GAL, bbl, lb, cf, REV, scf, Nm³, NL, P or no unit.• Selectable on-screen time units for flow rate:/sec, /min, /hour or /day.• Number of digits for flow rate: 5½.• Piegraph indication: ten segments.• Green or amber LED backlight with adjustable intensity.• Auto backup of settings in EEPROM memory.• Operational temperature: -40°C to +80°C (-40°F to 178°F).• Easy configuration with clear alphanumerical display.• Very compact design for panel mount, wall mount or field mount applications.• Rugged aluminum or GRP field mount enclosure IP67 / NEMA4X.
ApplicationsFlow measurement where a local flow rate indication is required without signal re-transmission or totalizer functionality.Alternative advanced models: F012, F013, F014, F016.Even more advanced models: F110 and higher.
Flowmeter Inputs• Pulse type inputs:Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.• (0)4 – 20mA.• 0 – 10V DC.
Pulse Outputs• None.
Alarm Outputs• None.
Analog Outputs• None.
Power Supply• Battery.• 4 – 20mA. Input Loop-powered.• 8 – 24V AC/DC.• 115 – 230V AC.
Sensor Supply• 3.2, 8.2, 12, 24V DC.
Intrinsically Safe• ATEX: II 1 G Ex ia IIC T4 II 1 D Ex iaD 20 IP 65 / 67 T 100 °C• IECEx: Ga Ex ia IIC T4 Ex iaD 20 IP65 / 67 T100 °C• CSA:I.S. Class I / II / III, Div. 1, Grps A...G, T4Class I, Zone 0, AEx ia IIC T4• FM:I.S. Class I / II / III, Div. 1, Grps A...G, T4Class I, Zone 0, AEx ia IIC T4
Explosion Proof• ATEX: II 2 GD EEx d IIB T5
CommunicationOnly available on F1-Series products.