Features• Eight point linearization of the flow curve - with interpolation.• Scaled pulse output reflecting the accumulated total.• Displays total and flow rate simultaneously.• Large digit selection for flow rate or total.• Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.• Total - resettable: seven 17mm (0.67") digits.• Accumulated total - not resettable: eleven 8mm (0.31") digits.• Separate engineering units for flow rate and total.• Green or amber LED backlight with adjustable intensity.• Auto backup of settings and running totals in EEPROM memory.• Operational temperature: -40°C to +80°C (-40°F to 178°F).• Easy configuration with clear alphanumerical display.• Very compact design for panel mount, wall mount or field mount applications.• Rugged aluminum or GRP field mount enclosure IP67 / NEMA4X.
ApplicationsLiquid flow measurement with mechanic flowmeters where a precise calculation over the full measurement range is required.Alternative advanced models: F112, F118.
Flowmeter Inputs• Pulse type inputs:Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.• (0)4 – 20mA.• 0 – 10V DC.
Pulse Outputs• Function: Scaled pulse output according to accumulated total (e.g. one pulse every 3.25 gallons). Max. frequency: 500Hz. Adjustable pulse length from 1 msec. to 10 seconds.• Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay.
Alarm Outputs• None.
Analog Outputs• None.
Power Supply• Battery.• 4 – 20mA. Input Loop-powered.• 8 – 24V AC/DC.• 115 – 230V AC.
Sensor Supply• 3.2, 8.2, 12, 24V DC.
Intrinsically Safe• ATEX: II 1 G Ex ia IIC T4 II 1 D Ex iaD 20 IP 65 / 67 T 100 °C• IECEx: Ga Ex ia IIC T4 Ex iaD 20 IP65 / 67 T100 °C• CSA:I.S. Class I / II / III, Div. 1, Grps A...G, T4Class I, Zone 0, AEx ia IIC T4• FM:I.S. Class I / II / III, Div. 1, Grps A...G, T4Class I, Zone 0, AEx ia IIC T4
Explosion Proof• ATEX: II 2 GD EEx d IIB T5
CommunicationOnly available on F1-Series products.