Features• Two competely separated flow rate / totalizers.• For each flow one scaled pulse output.• Displays total, flow rate and product I.D. simultaneously.• Large digit selection for flow rate or total.• Flow rates: seven 17mm (0.67") or 8mm (0.31") digits.• Totals - resettable: seven 17mm (0.67") digits.• Accumulated totals - not resettable: eleven 8mm (0.31") digits.• Separate engineering units for flow rates and totals on the display.• Green LED backlight.• Auto backup of settings and running totals in EEPROM memory.• Operational temperature: -30°C to +80°C (-22°F to 178°F).• Very compact design for panel mount, wall mount or field mount applications.• Rugged aluminum or GRP field mount enclosure IP67 / NEMA4X.
ApplicationsFor those applications where two indicators are required but one single and compact enclosure is desired.Alternative basic model: two separate F014’s.
Flowmeter Inputs• Pulse type inputs:Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.Different pulse signal types are allowed for input A and B.• (0)4 – 20mA.• 0 – 10V DC.
Pulse Outputs• Function: Scaled pulse output according accumulated total (e.g. a pulse every 3.25 gallons and a pulse every 50.0 liters).Max. frequency: 64Hz.Adjustable pulse length from 8 msec. to 2 seconds.• Type: Two passive NPN transistors, active PNP transistors or isolated electro-mechanical relays.
Alarm Outputs• None.
Analog Outputs• None.
Power Supply• Battery.• 4 – 20mA Loop-powered.• 8 – 24V AC/DC.• 115 – 230V AC.
Sensor Supply• 3.2, 8.2, 12, 24V DC.
Intrinsically Safe• ATEX: II 1 GD EEx ia IIB/IIC T4 T 100 °C
Explosion Proof• ATEX: II 2 G EEx d IIB T5
CommunicationFunction: All process data and settings can be read and modified through the communication link.Protocol: Modbus ASCII / RTU.Interface: RS232 / RS485 2-wire or 4-wire / TTL.