Features• Fifteen point linearization of the flow curve - with interpolation.• Analog and pulse outputs.• Displays total and flow rate simultaneously.• Large digit selection for flow rate or total.• Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.• Total - resettable: seven 17mm (0.67") digits.• Accumulated total - not resettable: eleven 8mm (0.31") digits.• Separate engineering units for flow rate and total on the display.• Green LED backlight.• Auto backup of settings and running totals in EEPROM memory.• Operational temperature: -40°C to +80°C (-40°F to 176°F).• Very compact design for panel mount, wall mount or field mount applications.• Rugged aluminum or GRP field mount enclosure IP67 / NEMA4X.
ApplicationsLiquid flow measurement with mechanic flowmeters where a precise calculation over the full measurement range is required. Also re-transmission of the flow rate and/or totalizer functions or serial communication is desired.Alternative basic model: F016.Alternative advanced model: F118.
Flowmeter Inputs• Pulse type inputs:Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.• (0)4 – 20mA.• 0 – 10V DC.
Status Inputs• Remote control: external reset for clearing total or to disable manual clearing through the keypad.
Pulse Outputs• Function: Scaled pulse output according to linearized accumulated total (e.g. a pulse every 3.25 gallons).Max. frequency: 64Hz.Adjustable pulse length from 8 msec. to 2 seconds.• Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay.
Alarm Outputs• None.
Analog Outputs• Function: Re-transmitting the linearized flow rate - the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).• Type: One passive isolated, floating or loop powered 4 – 20mA output or one active (0)4 – 20mA or 0 – 10V DC output.
Power Supply• Battery.• 4 – 20mA Loop-powered.• 8 – 24V AC/DC.• 115 – 230V AC.
Sensor Supply• 3.2, 8.2, 12, 24V DC.
Intrinsically Safe• ATEX: II 1 G Ex ia IIB/IIC T4 Ga II 1 D Ex ia IIIC T100 °C Da IP6X• IECEx: Ex ia IIC/IIB T4 Ga Ex ia IIIC T100 °C Da IP6X
Explosion Proof• ATEX: II 2 G EEx d IIB T5
CommunicationFunction: All process data and settings can be read and modified through the communication link.Protocol: Modbus RTU.Interface: RS232 / RS485 2-wire or 4-wire / TTL.