Features• Calculates differential flow rate (consumption), total and accumulated total of flow A and B.• Calculates the sum flow rate, total and accumulated total of flow A and B.• Precautions for pulsating flows and very low consumption readings.• Analog and pulse outputs.• Displays total and flow rate simultaneously.• Large digit selection for flow rate or total.• Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.• Total - resettable: seven 17mm (0.67") digits.• Accumulated total - not resettable: eleven 8mm (0.31") digits.• Separate engineering units for flow rate and total on the display.• Green LED backlight.• Auto backup of settings and running totals in EEPROM memory.• Operational temperature: -40°C to +80°C (-40°F to 176°F).• Very compact design for panel mount, wall mount or field mount applications.• Rugged aluminum or GRP field mount enclosure IP67 / NEMA4X.
ApplicationsDifferential function: fuel consumption calculation for diesel engines on board of ships or locomotives.Sum function: where flows are split-up in two pipe-lines and total flow has to be calculated.Alternative advanced model: F127.
Flowmeter Inputs• Pulse type inputs:Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.Different pulse signal types are allowed for input A and B.• (0)4 – 20mA.• 0 – 10V DC.
Pulse Outputs• Function: Scaled pulse output according to differential or totalized accumulated total (e.g. a pulse every 3.25 gallons).Max. frequency: 64Hz. Adjustable pulse length from 8 msec. to 2 seconds. The directional output is switched as soon as the pulse output reflects a "negative" differential.• Type: Two passive NPN transistors, active PNP transistors or isolated electro-mechanical relays.
Alarm Outputs• None.
Analog Outputs• Function: Re-transmitting the differential or totalized flow rate - the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).• Type: One passive isolated, floating or loop powered 4 – 20mA output or one active (0)4 – 20mA or 0 – 10V DC output.
Power Supply• Battery.• 4 – 20mA Loop-powered.• 8 – 24V AC/DC.• 115 – 230V AC.
Sensor Supply• 3.2, 8.2, 12, 24V DC.
Intrinsically Safe• ATEX: II 1 G Ex ia IIB/IIC T4 Ga II 1 D Ex ia IIIC T100 °C Da IP6X• IECEx: Ex ia IIC/IIB T4 Ga Ex ia IIIC T100 °C Da IP6X
Explosion Proof• ATEX: II 2 G EEx d IIB T5
CommunicationFunction: All process data and settings can be read and modified through the communication link.Protocol: Modbus RTU.Interface: RS232 / RS485 2-wire or 4-wire / TTL.