Features• Calculates and controls the ratio between flow A and flow B.Formula: ratio = additive / main• Three control modes:- Hand (manual valve control)- Local Setpoint (control additive flow only)- Ratio (control additive flow to obtain the desired ratio).• Bumpless transistion between the control modes.• Displays actual and desired ratio simultaneously, flow rate A and flow rate B.• Safety mode to place the valve in a safe position• Analog output to control the position of the valve.• Ratio: seven 17mm (0.67") digits, displayed as percentage.Desired ratio: five 8mm (0.31") digits.• Flow rate A and B: seven 17mm (0.67") digits.• Ratio monitoring: two alarm values can be set: low and high ratio alarm.• Displays clear alarm messages.• Green LED backlight.• Auto backup of settings, setpoint and control mode in EEPROM memory.• Operational temperature: -30°C to +80°C (-22°F to 178°F).• Very compact design for panel mount, wall mount or field mount applications.• Rugged aluminum or GRP field mount enclosure IP67 / NEMA4X.
ApplicationsApplications where a constant ratio between a main flow and an addititve flow is desired (e.g. applications like glueing, blending or mixing) without the need to manually control the additive flow.
Flowmeter Inputs• Pulse type inputs:Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.Different pulse signal types are allowed for input A and B.
Status Inputs• Remote control: Safety mode which stops the control process and places the valve in a safe position.
Pulse Outputs• None.
Alarm Outputs• Function: Two alarm outputs for low and high ratio alarm.• Type: Two passive NPN transistors, active PNP transistors or isolated electro-mechanical relays.
Analog Outputs• Function: Control output to position the valve of the additive flow.• Type: One passive isolated, floating or loop powered 4 – 20mA output or one active (0)4 – 20mA or 0 – 10V DC output.
Power Supply• Battery.• 4 – 20mA Output loop-powered.• 8 – 24V AC/DC.• 115 – 230V AC.
Sensor Supply• 3.2, 8.2, 12, 24V DC.
Intrinsically Safe• ATEX: II 1 GD EEx ia IIB/IIC T4 T 100 °C
Explosion Proof• ATEX: II 2 G EEx d IIB T5
CommunicationFunction: All process data and settings can be read and modified through the communication link.Protocol: Modbus RTU.Interface: RS232 / RS485 2-wire or 4-wire / TTL.