Features• Receipt printing function after each batch.• Large display shows preset value and running batch value simultaneously.• Two-stage control for batching larger quantities.• Self-learning overrun correction.• Easy operation to enter a batch value and to control the process.• Count-up and count-down function available.• Actual batched quantity: seven 17mm (0.67") digits.• Preset value: seven 17mm (0.67") digits during programming and 8mm (0.31") digits during batchprocess.• Total - resettable: seven 17mm (0.67") digits.• Accumulated total - not resettable: eleven 8mm (0.31") digits.• Green LED backlight.• Auto backup of settings and running totals in EEPROM memory.• Operational temperature: -40°C to +80°C (-40°F to 176°F).• Very compact design for panel mount, wall mount or field mount applications.• Rugged aluminum or GRP field mount enclosure IP67 / NEMA4X.
ApplicationsFor batching of small and /or large quantities, single or repeating batches where printed information is requested.Alternative basic model: F030.Alternative advanced models: F131, F136.Even more advanced models: 300-Series.
Flowmeter Inputs• Pulse type inputs:Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
Status Inputs• Remote control: start.• Remote control: pause / stop.
Pulse Outputs• None.
Alarm Outputs• None.
Analog Outputs• None.
Control Outputs• Function: Control outputs for one- or two-stage batching with active overrun correction.• Type: Two passive NPN transistors, active PNP transistors or isolated electro-mechanical relays.
Power Supply• Battery.• 4 – 20mA Loop-powered.• 8 – 24V AC/DC.• 115 – 230V AC.
Sensor Supply• 3.2, 8.2, 12, 24V DC.
Intrinsically Safe• ATEX: II 1 G Ex ia IIB/IIC T4 Ga II 1 D Ex ia IIIC T100 °C Da IP6X• IECEx: Ex ia IIC/IIB T4 Ga Ex ia IIIC T100 °C Da IP6X
Explosion Proof• ATEX: II 2 G EEx d IIB T5
CommunicationFunction: Send the "print receipt" data after every batch.Protocol: ASCII data.Interface: RS232 / RS485 2-wire or 4-wire / TTL.Remark: There is no handshaking or interfacing with the printer. Data is sent with plain ASCII characters.