Features• Valve position calculated through bi-directional flow measurement.• Displays the position as 0 - 100%, the moved volume and "open / closed" texts.• Analog output mirrors the position of the valve.• Modbus communication link for remote monitoring.• Re-calibration feature.• Service counter displays the number of full strokes.• Easy configuration with clear alphanumeric display.• Quadrature input to detect the direction of flow.• Green LED backlight.• Backup of settings in EEPROM memory.• Operational temperature: -30°C to +80°C (-22°F to 178°F).• Very compact design for panel mount, wall mount or field mount applications.• Rugged aluminum or GRP field mount enclosure IP67 / NEMA4X.
ApplicationsValve position indication and monitoring in hydraulic systems. For example as valve position indicator VPI for ballast tanks in ships.
Flowmeter Inputs• Pulse type inputs:Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
Pulse Outputs• Function: Scaled pulse output according to the bi-directional accumulated total (e.g. a pulse every 3.25 gallons).Max. frequency: 64Hz.Adjustable pulse length from 8 msec. to 2 seconds. The directional switch output is switched as soon as the pulse output reflects a "negative" quantity.• Type: Two passive NPN transistors, active PNP transistors or isolated electro-mechanical relays.
Alarm Outputs• None.
Analog Outputs• Function: Re-transmitting the position of the hydraulic systems - the output can be scaled to any range (e.g. from 0% to 110%).• Type: One passive isolated, floating or loop powered 4 – 20mA output or one active (0)4 – 20mA or 0 – 10V DC output.
Power Supply• Battery.• 4 – 20mA Loop-powered.• 8 – 24V AC/DC.• 115 – 230V AC.
Sensor Supply• 8.2, 12, 24V DC.
Intrinsically Safe• ATEX: II 1 GD EEx ia IIB/IIC T4 T 100 °C
Explosion Proof• ATEX: II 2 G EEx d IIB T5
CommunicationFunction: All process data and settings can be read and modified through the communication link.Protocol: Modbus RTU.Interface: RS232 / RS485 2-wire or 4-wire / TTL.