F010

Safe area / Intrinsically safe - Flow rate Indicator

with very large digits

Product description

The F010 is a local indicator with large 26mm (1") high digits which displays the actual flow rate. The measuring and time unit to be displayed below the flow rate are simply selected through an alphanumeric configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user-friendly solution! The configuration of K-factors or Span and number of decimals is done through software functions, without any sensitive DIP-switches or trimmers.

Advantages
  • Robust aluminum or stainless steel 316L field enclosure (IP65, IP67 / NEMA Type4X) .
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available - ATEX, IECEx, FM and CSA approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.

Downloads

Thank you

You will receive a email with the download link soon.

Please fill in the form below to receive the download



Features

  • Displays instantaneous flow rate, measuring and time unit.
  • Very large 26mm (1") high digits for flow rate.
  • Selectable on-screen engineering units for flow rate: mL, L, m³, mg, g, kg, ton, GAL, bbl, lb, cf, REV, scf, Nm³, NL, P or no unit. Time units for flow rate: /sec, /min, /hour or /day.
  • Number of digits for flow rate: 5½.
  • Piegraph indication: ten segments.
  • LED backlight with adjustable intensity.
  • Intrinsically safe according ATEX, IECEx, FM and CSA C-US.
  • GRP, Aluminum or high grade stainless steel enclosure.
  • Auto backup of settings in EEPROM memory.
  • Easy configuration with clear alphanumerical display.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.

Applications

  • The F010 fits in flow measurement applications where a local flow rate indication is required without signal re-transmission or totalizer functionality.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Product specifications

  • Signal Inputs

    • Flowmeter Inputs

      • Pulse type inputs:
        Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
      • (0)4 – 20mA.
      • 0 – 10V DC.
  • Signal Outputs

    • Pulse outputs

      • None.
    • Alarm outputs

      • None.
    • Analog outputs

      • None.
  • Supply

    • Power Supply

      • Long life Lithium battery.
      • 4 – 20mA, input Loop-powered.
      • 8 – 24V AC/DC.
      • 115 – 230V AC.
      • Basic: 8 - 30V DC.
    • Sensor Supply

      • 3.2, 8.2, 12, 24V DC.
  • Hazardous Area

    • Intrinsically Safe

      • ATEX:
        Gas: II 1 G Ex ia IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T200 100 °C Da
      • IECEx:
        Gas: Ex ia IIC T4 Ga
        Dust: Ex ia IIIC T200 100 °C Da
      • CSA & FM:
        I.S. Class I/II/III, Div 1, Grp A...G, T4
        Class I, Zone 0, AEx ia IIC T4 Ga
        Note: Extended aluminum enclosures not available with CSA/FM approval.
    • Explosion Proof

      • ATEX/IECEx:
        Gas: II 2 G Ex db IIB+H2 T5 Gb
        Dust: II 2 D Ex tb IIIC T80°C Db
  • Communication

      • Modbus communication available on F1-Series products.
      • HART communication is available with the F018 Flow rate Monitor / Totalizer.

Questions and answers

No questions have been asked about this article yet.

Ask a question

Thank you

Your question has been forwarded to our support team.
We will answer it as soon as possible.

Ask a question



F011

Safe area / Intrinsically safe - Totalizer

with resettable total and non-resettable accumulated total

Product description

The F011 is a local indicator which displays the running total and accumulated total simultaneously. Total can be reset to zero by pressing the CLEAR button twice. The accumulated total can register up to 11 digits and is backed-up in EEPROM memory every minute, just as the running total. The measuring unit to be displayed is simply selected through an alphanumeric configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user-friendly solution!

Advantages
  • Robust aluminum or stainless steel 316L field enclosure (IP65, IP67 / NEMA Type4X) .
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available - ATEX, IECEx, FM and CSA approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.

Downloads

Thank you

You will receive a email with the download link soon.

Please fill in the form below to receive the download



Features

  • Displays total and accumulated total simultaneously.
  • Total - resettable: seven 17mm (0.67") digits.
  • Accumulated total - not resettable: eleven 8mm (0.31") digits.
  • Selectable on-screen engineering units for total: ml, L, m³, GAL, USGAL, kg, lb, bbl or no unit.
  • LED backlight with adjustable intensity.
  • Auto backup of settings and running totals in EEPROM memory.
  • Intrinsically safe according ATEX, IECEx, FM and CSA C-US.
  • GRP, Aluminum or high grade stainless steel enclosure.
  • Easy configuration with clear alphanumerical display.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.

Applications

  • Flow measurement where a local totalizer function is required without flow rate or signal re-transmission functionality.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Product specifications

  • Signal Inputs

    • Flowmeter Inputs

      • Pulse type inputs:
        Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
      • (0)4 – 20mA.
  • Signal Outputs

    • Pulse outputs

      • None.
    • Alarm outputs

      • None.
    • Analog outputs

      • None.
  • Supply

    • Power Supply

      • Long life Lithium battery.
      • 4 – 20mA, input Loop-powered.
      • 8 – 24V AC/DC.
      • 115 – 230V AC.
      • Basic: 8 - 30V DC.
    • Sensor Supply

      • 3.2, 8.2, 12, 24V DC.
  • Hazardous Area

    • Intrinsically Safe

      • ATEX:
        Gas: II 1 G Ex ia IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T200 100 °C Da
      • IECEx:
        Gas: Ex ia IIC T4 Ga
        Dust: Ex ia IIIC T200 100 °C Da
      • CSA & FM:
        I.S. Class I/II/III, Div 1, Grp A...G, T4
        Class I, Zone 0, AEx ia IIC T4 Ga
        Note: Extended aluminum enclosures not available with CSA/FM approval.
    • Explosion Proof

      • ATEX/IECEx:
        Gas: II 2 G Ex db IIB+H2 T5 Gb
        Dust: II 2 D Ex tb IIIC T80°C Db
  • Communication

      • Modbus communication available on F1-Series products.
      • HART communication is available with the F018 Flow rate Monitor / Totalizer.

Questions and answers

No questions have been asked about this article yet.

Ask a question

Thank you

Your question has been forwarded to our support team.
We will answer it as soon as possible.

Ask a question



F012

Safe area / Intrinsically safe - Flow rate Indicator / Totalizer

displays flow rate and total simultaneously

Product description

The F012 is our most popular model. This local indicator displays the actual flow rate, total and accumulated total. Total can be reset to zero by pressing the CLEAR button twice. The accumulated total can register up to 11 digits and is backed-up in EEPROM memory every minute, just as the running total.
On-screen engineering units are easily configured from a comprehensive selection.

Advantages
  • Robust aluminum or stainless steel 316L field enclosure (IP65, IP67 / NEMA Type4X) .
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available - ATEX, IECEx, FM and CSA approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.

Downloads

Thank you

You will receive a email with the download link soon.

Please fill in the form below to receive the download



Features

  • Displays total and flow rate simultaneously and additional accumulated total.
  • Large digit selection for flow rate or total.
  • Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.
  • Total - resettable: seven 17mm (0.67") digits.
  • Accumulated total - not resettable: eleven 8mm (0.31") digits.
  • Separate engineering units for flow rate and total.
  • Selectable on-screen engineering units for flow rate: mL, L, m³, mg, g, kg, ton, GAL, bbl, lb, cf, REV, scf, Nm³, NL, P or no unit. Time units for flow rate: /sec, /min, /hour or /day.
  • Selectable on-screen engineering units for total: ml, L, m³, GAL, USGAL, kg, lb, bbl or no unit.
  • LED backlight with adjustable intensity.
  • Intrinsically safe according ATEX, IECEx, FM and CSA C-US.
  • GRP, Aluminum or high grade stainless steel enclosure.
  • Auto backup of settings and running totals in EEPROM memory.
  • Easy configuration with clear alphanumerical display.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.

Applications

  • Flow measurement where a local flow rate indication and totalizer function is required without signal re-transmission.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Product specifications

  • Signal Inputs

    • Flowmeter Inputs

      • Pulse type inputs:
        Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
      • (0)4 – 20mA.
  • Signal Outputs

    • Pulse outputs

      • None.
    • Alarm outputs

      • None.
    • Analog outputs

      • None.
  • Supply

    • Power Supply

      • Long life Lithium battery.
      • 4 – 20mA, input Loop-powered.
      • 8 – 24V AC/DC.
      • 115 – 230V AC.
      • Basic: 8 - 30V DC.
    • Sensor Supply

      • 3.2, 8.2, 12, 24V DC.
  • Hazardous Area

    • Intrinsically Safe

      • ATEX:
        Gas: II 1 G Ex ia IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T200 100 °C Da
      • IECEx:
        Gas: Ex ia IIC T4 Ga
        Dust: Ex ia IIIC T200 100 °C Da
      • CSA & FM:
        I.S. Class I/II/III, Div 1, Grp A...G, T4
        Class I, Zone 0, AEx ia IIC T4 Ga
        Note: Extended aluminum enclosures not available with CSA/FM approval.
    • Explosion Proof

      • ATEX/IECEx:
        Gas: II 2 G Ex db IIB+H2 T5 Gb
        Dust: II 2 D Ex tb IIIC T80°C Db
  • Communication

      • Modbus communication available on F1-Series products.
      • HART communication is available with the F018 Flow rate Monitor / Totalizer.

Questions and answers

No questions have been asked about this article yet.

Ask a question

Thank you

Your question has been forwarded to our support team.
We will answer it as soon as possible.

Ask a question



F013

Safe area / Intrinsically safe - Flow rate Monitor / Totalizer

with one high / low alarm output

Product description

The F013 is a versatile flow rate indicator and totalizer with continuous flow rate monitoring feature. It has one low flow rate and one high flow rate alarm value. If desired, an alarm ignore function can be set up to allow for an incorrect flow rate for a certain period of time. The display shows flow rate, total, accumulated total, alarm values and alarm messages. On-screen engineering units are easily configured from a comprehensive selection.

Advantages
  • Robust aluminum or stainless steel 316L field enclosure (IP65, IP67 / NEMA Type4X) .
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available - ATEX, IECEx, FM and CSA approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.

Downloads

Thank you

You will receive a email with the download link soon.

Please fill in the form below to receive the download



Features

  • The display shows flow rate, total, accumulated total, alarm values and alarm messages.
  • Large digit selection for flow rate or total.
  • Displays clear alarm messages.
  • Red flashing LED backlight in case of a flow rate alarm; intensity adjustable.
  • Flow rate monitoring: two alarm values can be set: low and high flow rate alarm.
  • Alarm values can be changed by the operator or they can be password protected.
  • One alarm output for high, low or both combined flow rate alarms.
  • Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.
  • Total - resettable: seven 17mm (0.67") digits.
  • Accumulated total - not resettable: eleven 8mm (0.31") digits.
  • Separate engineering units for flow rate and total.
  • Intrinsically safe according ATEX, IECEx, FM and CSA C-US.
  • GRP, Aluminum or high grade stainless steel enclosure.
  • Auto backup of settings and running totals in EEPROM memory.
  • Easy configuration with clear alphanumerical display.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.

Applications

  • Flow measurement where continuous flow rate monitoring is important without signal re-transmission.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Product specifications

  • Signal Inputs

    • Flowmeter Inputs

      • Pulse type inputs:
        Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
      • (0)4 – 20mA.
  • Signal Outputs

    • Pulse outputs

      • None.
    • Alarm outputs

      • Function: Configurable alarm output for high, low or both combined flow rate alarms.
      • Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay.
    • Analog outputs

      • None.
  • Supply

    • Power Supply

      • Long life Lithium battery.
      • 4 – 20mA, input Loop-powered.
      • 8 – 24V AC/DC.
      • 115 – 230V AC.
      • Basic: 8 - 30V DC.
    • Sensor Supply

      • 3.2, 8.2, 12, 24V DC.
  • Hazardous Area

    • Intrinsically Safe

      • ATEX:
        Gas: II 1 G Ex ia IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T200 100 °C Da
      • IECEx:
        Gas: Ex ia IIC T4 Ga
        Dust: Ex ia IIIC T200 100 °C Da
      • CSA & FM:
        I.S. Class I/II/III, Div 1, Grp A...G, T4
        Class I, Zone 0, AEx ia IIC T4 Ga
        Note: Extended aluminum enclosures not available with CSA/FM approval.
    • Explosion Proof

      • ATEX/IECEx:
        Gas: II 2 G Ex db IIB+H2 T5 Gb
        Dust: II 2 D Ex tb IIIC T80°C Db
  • Communication

      • Modbus communication available on F1-Series products.
      • HART communication is available with the F018 Flow rate Monitor / Totalizer.

Questions and answers

No questions have been asked about this article yet.

Ask a question

Thank you

Your question has been forwarded to our support team.
We will answer it as soon as possible.

Ask a question



F014

Safe area / Intrinsically safe - Flow rate Indicator / Totalizer

with pulse output

Product description

The F014 is a local indicator / transmitter which displays the actual flow rate, total and accumulated total. A scaled pulse, related to the accumulated total is generated for re-transmitting the count on the display. Total can be reset to zero by pressing the CLEAR button twice. The accumulated total can register up to 11 digits and is backed-up in EEPROM memory every minute, just as the running total.
On-screen engineering units are easily configured from a comprehensive selection.

Advantages
  • Robust aluminum or stainless steel 316L field enclosure (IP65, IP67 / NEMA Type4X) .
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available - ATEX, IECEx, FM and CSA approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.

Downloads

Thank you

You will receive a email with the download link soon.

Please fill in the form below to receive the download



Features

  • Displays total and flow rate simultaneously and additional accumulated total.
  • Large digit selection for flow rate or total.
  • Selectable on-screen engineering units for flow rate: mL, L, m³, mg, g, kg, ton, GAL, bbl, lb, cf, REV, scf, Nm³, NL, P or no unit. Time units for flow rate: /sec, /min, /hour or /day.
  • Selectable on-screen engineering units for total: ml, L, m³, GAL, USGAL, kg, lb, bbl or no unit.
  • Scaled pulse output reflecting the accumulated total.
  • Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.
  • Total - resettable: seven 17mm (0.67") digits.
  • Accumulated total - not resettable: eleven 8mm (0.31") digits.
  • Separate engineering units for flow rate and total.
  • LED backlight with adjustable intensity.
  • Intrinsically safe according ATEX, IECEx, FM and CSA C-US.
  • GRP, Aluminum or high grade stainless steel enclosure.
  • Auto backup of settings and running totals in EEPROM memory.
  • Easy configuration with clear alphanumerical display.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.

Applications

  • Flow measurement where re-transmission of the totalizer function is required.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Product specifications

  • Signal Inputs

    • Flowmeter Inputs

      • Pulse type inputs:
        Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
      • (0)4 – 20mA.
  • Signal Outputs

    • Pulse outputs

      • Function: Scaled pulse output according to accumulated total (e.g. one pulse every 3.25 gallons).
        Max. frequency: 500Hz.
        Adjustable pulse length from 1 msec. to 10 seconds.
      • Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay.
    • Alarm outputs

      • None.
    • Analog outputs

      • None.
  • Supply

    • Power Supply

      • Long life Lithium battery.
      • 4 – 20mA, input Loop-powered.
      • 8 – 24V AC/DC.
      • 115 – 230V AC.
      • Basic: 8 - 30V DC.
    • Sensor Supply

      • 3.2, 8.2, 12, 24V DC.
  • Hazardous Area

    • Intrinsically Safe

      • ATEX:
        Gas: II 1 G Ex ia IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T200 100 °C Da
      • IECEx:
        Gas: Ex ia IIC T4 Ga
        Dust: Ex ia IIIC T200 100 °C Da
      • CSA & FM:
        I.S. Class I/II/III, Div 1, Grp A...G, T4
        Class I, Zone 0, AEx ia IIC T4 Ga
        Note: Extended aluminum enclosures not available with CSA/FM approval.
    • Explosion Proof

      • ATEX/IECEx:
        Gas: II 2 G Ex db IIB+H2 T5 Gb
        Dust: II 2 D Ex tb IIIC T80°C Db
  • Communication

      • Modbus communication available on F1-Series products.
      • HART communication is available with the F018 Flow rate Monitor / Totalizer.

Questions and answers

No questions have been asked about this article yet.

Ask a question

Thank you

Your question has been forwarded to our support team.
We will answer it as soon as possible.

Ask a question



F016

Safe area / Intrinsically safe - Flow rate Indicator / Totalizer

with linearization and pulse output

Product description

The F016 is a local indicator / transmitter which displays the actual flow rate, total and accumulated total. In addition to the average K-Factor or Span, eight linearization points can be entered with their frequencies or values. The unit will interpolate between these points, greatly enhancing accuracy in any flow range, even for very low frequency applications. This linearization affects all displayed information as well as the pulse output. On-screen engineering units are easily configured from a comprehensive selection.

Advantages
  • Robust aluminum or stainless steel 316L field enclosure (IP65, IP67 / NEMA Type4X) .
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available - ATEX, IECEx, FM and CSA approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.

Downloads

Thank you

You will receive a email with the download link soon.

Please fill in the form below to receive the download



Features

  • Displays total and flow rate simultaneously and additional accumulated total.
  • Large digit selection for flow rate or total.
  • Selectable on-screen engineering units for flow rate: mL, L, m³, mg, g, kg, ton, GAL, bbl, lb, cf, REV, scf, Nm³, NL, P or no unit. Time units for flow rate: /sec, /min, /hour or /day.
  • Selectable on-screen engineering units for total: ml, L, m³, GAL, USGAL, kg, lb, bbl or no unit.
  • Eight point linearization of the flow curve - with interpolation.
  • Scaled pulse output reflecting the accumulated total.
  • Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.
  • Total - resettable: seven 17mm (0.67") digits.
  • Accumulated total - not resettable: eleven 8mm (0.31") digits.
  • Separate engineering units for flow rate and total.
  • LED backlight with adjustable intensity.
  • Intrinsically safe according ATEX, IECEx, FM and CSA C-US.
  • GRP, Aluminum or high grade stainless steel enclosure.
  • Auto backup of settings and running totals in EEPROM memory.
  • Easy configuration with clear alphanumerical display.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.

Applications

  • Liquid flow measurement with mechanic flowmeters where a precise calculation over the full measurement range is required.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Product specifications

  • Signal Inputs

    • Flowmeter Inputs

      • Pulse type inputs:
        Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
  • Signal Outputs

    • Pulse outputs

      • Function: Scaled pulse output according to accumulated total (e.g. one pulse every 3.25 gallons).
        Max. frequency: 500Hz.
        Adjustable pulse length from 1 msec. to 10 seconds.
      • Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay.
    • Alarm outputs

      • None.
    • Analog outputs

      • None.
  • Supply

    • Power Supply

      • Long life Lithium battery.
      • 8 – 24V AC/DC.
      • 115 – 230V AC.
      • Basic: 8 - 30V DC.
    • Sensor Supply

      • 3.2, 8.2, 12, 24V DC.
  • Hazardous Area

    • Intrinsically Safe

      • ATEX:
        Gas: II 1 G Ex ia IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T200 100 °C Da
      • IECEx:
        Gas: Ex ia IIC T4 Ga
        Dust: Ex ia IIIC T200 100 °C Da
      • CSA & FM:
        I.S. Class I/II/III, Div 1, Grp A...G, T4
        Class I, Zone 0, AEx ia IIC T4 Ga
        Note: Extended aluminum enclosures not available with CSA/FM approval.
    • Explosion Proof

      • ATEX/IECEx:
        Gas: II 2 G Ex db IIB+H2 T5 Gb
        Dust: II 2 D Ex tb IIIC T80°C Db
  • Communication

      • Modbus communication available on F1-Series products.
      • HART communication is available with the F018 Flow rate Monitor / Totalizer.

Questions and answers

No questions have been asked about this article yet.

Ask a question

Thank you

Your question has been forwarded to our support team.
We will answer it as soon as possible.

Ask a question



F018

Safe area / Intrinsically safe - Flow rate Monitor / Totalizer

with linearization, pulse/alarm and analog outputs and HART communication

Product description

The F018 is a local indicator / transmitter with linearization and continuous flow rate monitoring feature. It displays the actual linearized flow rate, resettable total and non-resettable accumulated total. The F-Series is known worldwide as a range of user-friendly indicators. The F018 is even more impressive. The HART communication allows you to communicate in an easy way with smart "DD enabled host" systems.

In addition to the average K-Factor or Span, fifteen linearization points can be entered with their frequencies or values. The unit will interpolate between these points greatly enhancing accuracy in any flow range, even for very low frequency applications. This linearization affects all displayed information as well as the signal outputs.

Advantages
  • Robust aluminum or stainless steel 316L field enclosure (IP65, IP67 / NEMA Type4X) .
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available - ATEX, IECEx, FM and CSA approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.

Downloads

Thank you

You will receive a email with the download link soon.

Please fill in the form below to receive the download



Features

  • The display shows flow rate, total, accumulated total, alarm values and alarm messages.
  • Large digit selection for flow rate or total.
  • Displays clear alarm messages.
  • Red flashing LED backlight in case of a flow rate alarm; intensity adjustable.
  • Fifteen point linearization of the flow curve - with interpolation.
  • Two alarm values can be entered: low and high flow rate alarm.
  • Pulse input retransmission, i.e. for calibration purposes or amplification and squaring of sinewave/coil signals.
  • Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.
  • Total - resettable: seven 17mm (0.67") digits.
  • Accumulated total - not resettable: eleven 8mm (0.31") digits.
  • Separate engineering units for flow rate and total.
  • Scaled pulse output reflecting the accumulated total.
  • Intrinsically safe according ATEX, IECEx, FM and CSA C-US.
  • GRP, Aluminum or high grade stainless steel enclosure.
  • Auto backup of settings and running totals in EEPROM memory.
  • Easy configuration with clear alphanumerical display.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.
  • F018 on the HART Foundation website.

Applications

  • Flow rate monitoring with a precise calculation over the full measurement range, where re-transmission of the totalizer and monitoring of the flow rate function and HART communication is required.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Product specifications

  • Signal Inputs

    • Flowmeter Inputs

      • Pulse type inputs:
        Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
  • Signal Outputs

    • Pulse outputs

      • Function: Scaled pulse output according to linearized accumulated total (e.g. a pulse every 3.25 gallons) and unscaled pulse input retransmission. Max. frequency: 500Hz.
        Retransmission: Minimum pulse duration: 50µs,
        Adjustable pulse length from 1 msec. Up to 10 seconds.
      • Type: One passive NPN transistor.
    • Alarm outputs

      • Function: Configurable alarm output for high, low or both combined flow rate alarms.
      • Type: One passive NPN transistor.
    • Analog outputs

      • Function: Re-transmitting the linearized flow rate, the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
      • Type: One galvanically isolated, loop powered 4 – 20mA output.
  • Supply

    • Power Supply

      • Long life Lithium battery.
      • 16 – 30V DC.
      • Basic: 8 - 30V DC.
      • Analog output loop powered.
    • Sensor Supply

      • 1.2 / 3.2 or 8.2V DC.
  • Hazardous Area

    • Intrinsically Safe

      • ATEX:
        Gas: II 1 G Ex ia IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T200 100 °C Da
      • IECEx:
        Gas: Ex ia IIC T4 Ga
        Dust: Ex ia IIIC T200 100 °C Da
      • CSA & FM:
        I.S. Class I/II/III, Div 1, Grp A...G, T4
        Class I, Zone 0, AEx ia IIC T4 Ga
        Note: Extended aluminum enclosures not available with CSA/FM approval.
    • Explosion Proof

      • For Explosion Proof applications we recommend the E-Series.
  • Communication

      • Function: All process data and settings can easily be read and modified through the HART communication link with all registered "DD enabled host" systems.
      • Protocol: HART, Revision 7.0.
      • Device specific DD can be downloaded at the dropdown downloads above .

Questions and answers

No questions have been asked about this article yet.

Ask a question

Thank you

Your question has been forwarded to our support team.
We will answer it as soon as possible.

Ask a question



F030

Safe area / Intrinsically safe - Batch Controller

with one control output

Product description

The F030 is a straight forward but easy-to-use batch controller. The operator can easily enter a batch quantity or execute repeating batches. During the batch, the preset value is displayed as well as the batched (or remaining) quantity and the units of measurement. The automatic self-learning overrun correction will ensure an accurate batch every time.
On-screen engineering units are easily configured from a comprehensive selection.

Advantages
  • Robust aluminum or stainless steel 316L field enclosure (IP65, IP67 / NEMA Type4X) .
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available - ATEX, IECEx, FM and CSA approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.

Downloads

Thank you

You will receive a email with the download link soon.

Please fill in the form below to receive the download



Features

  • Large display shows preset value and running batch value simultaneously.
  • Count-up and count-down function available.
  • Selectable on-screen engineering units for total: ml, L, m³, GAL, USGAL, kg, lb, bbl or no unit.
  • Actual batched quantity: seven 17mm (0.67") digits.
  • Preset value: seven 17mm (0.67") digits during programming and 8mm (0.31") digits during process .
  • Self-learning overrun correction.
  • One control output to drive a valve or pump.
  • Easy operation to enter a batch value and to control the process.
  • LED backlight with adjustable intensity.
  • Total - resettable: seven 17mm (0.67") digits.
  • Accumulated total - not resettable: eleven 8mm (0.31") digits.
  • Intrinsically safe according ATEX, IECEx, FM and CSA C-US.
  • GRP, Aluminum or high grade stainless steel enclosure.
  • Auto backup of settings and running totals in EEPROM memory.
  • Easy configuration with clear alphanumerical display.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.

Applications

  • For one stage batch applications at low or medium flow rates with single or repeating batches.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Product specifications

  • Signal Inputs

    • Flowmeter Inputs

      • Pulse type inputs:
        Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
      • (0)4 – 20mA.
    • Status Inputs

      • None.
  • Signal Outputs

    • Pulse outputs

      • None.
    • Alarm outputs

      • None.
    • Analog outputs

      • None.
    • Control outputs

      • Function: Control output for one-stage batching with active overrun correction.
      • Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay.
  • Supply

    • Power Supply

      • Long life Lithium battery.
      • 4 – 20mA, input Loop-powered.
      • 8 – 24V AC/DC.
      • 115 – 230V AC.
      • Basic: 8 - 30V DC.
    • Sensor Supply

      • 3.2, 8.2, 12, 24V DC.
  • Hazardous Area

    • Intrinsically Safe

      • ATEX:
        Gas: II 1 G Ex ia IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T200 100 °C Da
      • IECEx:
        Gas: Ex ia IIC T4 Ga
        Dust: Ex ia IIIC T200 100 °C Da
      • CSA & FM:
        I.S. Class I/II/III, Div 1, Grp A...G, T4
        Class I, Zone 0, AEx ia IIC T4 Ga
        Note: Extended aluminum enclosures not available with CSA/FM approval.
    • Explosion Proof

      • ATEX/IECEx:
        Gas: II 2 G Ex db IIB+H2 T5 Gb
        Dust: II 2 D Ex tb IIIC T80°C Db
  • Communication

      • Modbus communication available on F1-Series products.
      • HART communication is available with the F018 Flow rate Monitor / Totalizer.

Questions and answers

No questions have been asked about this article yet.

Ask a question

Thank you

Your question has been forwarded to our support team.
We will answer it as soon as possible.

Ask a question



F040

Safe area / Intrinsically safe - Temperature Indicator

with very large digits

Product description

The F040 is a straight forward temperature indicator with large 26mm (1") high digits. The measuring unit to be displayed below the temperature is simply selected through an alphanumeric configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user-friendly solution! The configuration of the Span, off-set and number of decimals is done through software functions, without any sensitive DIP-switches or trimmers.

Advantages
  • Robust aluminum or stainless steel 316L field enclosure (IP65, IP67 / NEMA Type4X) .
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available - ATEX, IECEx, FM and CSA approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.

Downloads

Thank you

You will receive a email with the download link soon.

Please fill in the form below to receive the download



Features

  • Displays actual temperature and measuring unit.
  • Very large 26mm (1") high digits for temperature.
  • Selectable on-screen engineering units:
    °C - °F - K.
  • Number of digits for temperature: 5½.
  • Piegraph indication: ten segments.
  • LED backlight with adjustable intensity.
  • Intrinsically safe according ATEX, IECEx, FM and CSA C-US.
  • GRP, Aluminum or high grade stainless steel enclosure.
  • Auto backup of settings in EEPROM memory.
  • Easy configuration with clear alphanumerical display.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.

Applications

  • Applications where a basic temperature measurement display is required without temperature monitoring or signal re-transmission.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Product specifications

  • Signal Inputs

    • Temperature Inputs

      • PT100 - 2, 3 or 4 wire PRTD sensor.
      • (0)4 – 20mA.
  • Signal Outputs

    • Alarm outputs

      • None.
    • Analog outputs

      • None.
  • Supply

    • Power Supply

      • Long life Lithium battery.
      • 4 – 20mA, input Loop-powered.
      • 8 – 24V AC/DC.
      • 115 – 230V AC.
      • Basic: 8 - 30V DC.
    • Sensor Supply

      • 8.2, 12, 24V DC.
  • Hazardous Area

    • Intrinsically Safe

      • ATEX:
        Gas: II 1 G Ex ia IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T200 100 °C Da
      • IECEx:
        Gas: Ex ia IIC T4 Ga
        Dust: Ex ia IIIC T200 100 °C Da
      • CSA & FM:
        I.S. Class I/II/III, Div 1, Grp A...G, T4
        Class I, Zone 0, AEx ia IIC T4 Ga
        Note: Extended aluminum enclosures not available with CSA/FM approval.
    • Explosion Proof

      • ATEX/IECEx:
        Gas: II 2 G Ex db IIB+H2 T5 Gb
        Dust: II 2 D Ex tb IIIC T80°C Db
  • Communication

      • Modbus communication available on F1-Series products.
      • HART communication is available with the F018 Flow rate Monitor / Totalizer.

Questions and answers

No questions have been asked about this article yet.

Ask a question

Thank you

Your question has been forwarded to our support team.
We will answer it as soon as possible.

Ask a question



F043

Safe area / Intrinsically safe - Temperature Monitor

with one high / low alarm output

Product description

The F043 is a versatile temperature indicator with continuous temperature monitoring feature. It has one low temperature and one high temperature alarm value. If desired, an ignore (delay) function can be set up to allow for an incorrect temperature for a certain period of time. The configuration of the Span, off-set and number of decimals is done through software functions, without any sensitive DIP-switches or trimmers.

Advantages
  • Robust aluminum or stainless steel 316L field enclosure (IP65, IP67 / NEMA Type4X) .
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available - ATEX, IECEx, FM and CSA approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell "Know one, know them all" configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.

Downloads

Thank you

You will receive a email with the download link soon.

Please fill in the form below to receive the download



Features

  • The display shows the actual temperature, alarm values, alarm messages and status.
  • On-screen engineering units are easily configured from a comprehensive selection.
  • Displays clear alarm messages.
  • Red flashing LED backlight in case of a temperature alarm; intensity adjustable.
  • Selectable on-screen engineering units:
    °C - °F - K.
  • Temperature: six large 17mm (0.67") digits.
  • Temperature monitoring: two alarm values can be set: low and high temperature alarm.
  • Alarm values can be changed by the operator or they can be password protected.
  • One alarm output for high, low or both combined temperature alarms.
  • Intrinsically safe according ATEX, IECEx, FM and CSA C-US.
  • GRP, Aluminum or high grade stainless steel enclosure.
  • Auto backup of settings in EEPROM memory.
  • Easy configuration with clear alphanumerical display.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.

Applications

  • For applications where continuous temperature measurement and monitoring is important without signal re-transmission.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Product specifications

  • Signal Inputs

    • Temperature Inputs

      • PT100 - 2, 3 or 4 wire PRTD sensor.
      • (0)4 – 20mA.
  • Signal Outputs

    • Alarm outputs

      • Function: Configurable alarm output for high, low or both combined temperature alarms.
      • Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay.
    • Analog outputs

      • None.
  • Supply

    • Power Supply

      • Long life Lithium battery.
      • 4 – 20mA, input Loop-powered.
      • 8 – 24V AC/DC.
      • 115 – 230V AC.
      • Basic: 8 - 30V DC.
    • Sensor Supply

      • 8.2, 12, 24V DC.
  • Hazardous Area

    • Intrinsically Safe

      • ATEX:
        Gas: II 1 G Ex ia IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T200 100 °C Da
      • IECEx:
        Gas: Ex ia IIC T4 Ga
        Dust: Ex ia IIIC T200 100 °C Da
      • CSA & FM:
        I.S. Class I/II/III, Div 1, Grp A...G, T4
        Class I, Zone 0, AEx ia IIC T4 Ga
        Note: Extended aluminum enclosures not available with CSA/FM approval.
    • Explosion Proof

      • ATEX/IECEx:
        Gas: II 2 G Ex db IIB+H2 T5 Gb
        Dust: II 2 D Ex tb IIIC T80°C Db
  • Communication

      • Modbus communication available on F1-Series products.
      • HART communication is available with the F018 Flow rate Monitor / Totalizer.

Questions and answers

No questions have been asked about this article yet.

Ask a question

Thank you

Your question has been forwarded to our support team.
We will answer it as soon as possible.

Ask a question



Login