N-Series instruction videos

Setting the printer output on the N-Series batch controllers

In this tutorial we will set the printer output of the N413 and N414 batch controllers. After each completed batch a receipt can be printed. Additional receipts can be printed on demand.

Explainer: Overrrun correction

An overrun may occur in a batch control process when the batch ends, and the control output deactivates the pump or valve. The remaining fluid in the system that has already passed will be added to the batch. This will cause an inaccurate batch volume.
Fluidwell batch controllers have a self-learning overrun correction. During a specific time, set by the operator, the controller analyzes the overrun volume of the batch and automatically corrects the end-of-batch timing of the control outputs.

How to set the preset value and start a batch on N-Series batch controllers

In this tutorial we will set the preset value, start and stop a batch and change the preset value again on the N-Series batch controllers. The preset is the value that represents the “to be delivered” or “batched” quantity.

How to set the control outputs on the N-Series batch controllers

In this tutorial we will set the control outputs on the Fluidwell N-Series batch controllers. In this example we will use a preset of 2000 Gallons and configure 1 relay output as 2-stage control output with a preclose of 100 Gallons. Followed by configuring 1 transistor output as a pump control output with a pre-open delay time of 5 seconds.