F-Series: F110

Field mount - Flow rate indicator / totalizer

with analog and pulse outputs

The F110 flow transmitter is the most popular model in our range of flow rate indicators / totalizers, complete with pulse and analog output signals. Even demanding applications are catered for with our base unit configuration.
The display shows flow rate, total and accumulated total. On-screen engineering units are easily configured from a comprehensive selection.

Advantages
  • Robust IP66, IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even stand on it!
  • Intrinsically Safe available - ATEX and IECEx approval for gas and dust applications.
  • Programming can be done by your own crew, with the sensible menu-driven structure, saving cost and irritation. Know one, know them all!
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.
Application overview F110

Features

  • Analog and pulse outputs.
  • Displays total and flow rate simultaneously.
  • Large digit selection for flow rate or total.
  • Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.
  • Total - resettable: seven 17mm (0.67") digits.
  • Accumulated total - not resettable: eleven 8mm (0.31") digits.
  • Separate engineering units for flow rate and total on the display.
  • Remote control input to reset total or to lock the "clear total" button.
  • LED backlight.
  • Auto backup of settings and running totals in EEPROM memory.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.
  • The F-Series is so rugged, even a truck can stand on it!

Flowmeter Inputs

  • Pulse type inputs:
    Reed-switch, open collector, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
  • (0)4 – 20mA.

Status Inputs

  • Remote control: external reset for clearing total or to disable manual clearing through the keypad.

Pulse Outputs

  • Function: Scaled pulse output according to accumulated total (e.g. a pulse every 3.25 gallons).
    Max. frequency: 500Hz.
    Adjustable pulse length from 0.001 sec. to 9.999 seconds.
  • Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay.

Alarm Outputs

  • None.

Analog Outputs

  • Function: Re-transmitting the flow rate - the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
  • Type: One passive isolated, floating or loop powered 4 – 20mA output or one active (0)4 – 20mA or 0 – 10V DC output.

Applications

  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).
  • Liquid flow measurement where re-transmission of the flow rate and/or totalizer functions or serial communication is required.
    Alternative basic model: F070.
    Alternative basic models: F010, F011, F012, F014. Alternative advanced models: F112, F113, F118 or the D-Series basic DIN panel mount indicators.

Power Supply

  • Long life Lithium battery.
  • 4 – 20mA Loop-powered.
  • 8 – 24V AC/DC.
  • 115 – 230V AC.
  • Basic: 8 - 30V DC.

Sensor Supply

  • 3.2, 8.2, 12, 24V DC.

Intrinsically Safe

  • ATEX:
    II 1 G Ex ia IIB/IIC T4 Ga
    II 1 D Ex ia IIIC T100 °C Da
  • IECEx:
    Ex ia IIC/IIB T4 Ga
    Ex ia IIIC T100 °C Da

Explosion Proof

  • ATEX:
    II 2 G / Ex d IIB T5 Gb
    II 2 D / Ex t IIIB T100°C Db

Communication
Function: All process data and settings can be read and modified through the communication link.
Protocol: Modbus ASCII / RTU.
Interface: RS232 / RS485 2-wire or 4-wire / TTL.
– HART communication is available with the F018 Flow rate Monitor / Totalizer.

LCD example F110